4. Troubleshooting
► Error Code
S6-3234
► Error message
Error: #S6-3234 / Failed connection to WPS. Try again or set up other wireless connection
► Symptom
WPS connection to AP is failed.
► Troubleshooting method
1) Retry the connection with WPS button.
► Error Code
S6-3235
S6-3236
► Error message
Error: #S6-3235 / Wi-Fi Direct is not ready. Turn off then on. Call for service if the problem persists
Error: #S6-3236 / Failed to connect to Wi-Fi Direct. Turn off your mobile device and turn it on
► Symptom
Wi-Fi Direct library is initialized.
► Troubleshooting method
1) Turn the machine off then on.
2) Change the wireless network settings. Retry it.
► Error Code
S7–2110
► Error message
Error #S7-2110 / Fuser Unit Failure: #S7-2110. Turn off then on. Call for service if the problem persists
► Symptom
Heat control relay operation is abnormal.
► Troubleshooting method
1) Turn the machine off. Re-install the fuser unit. Then turn the machine on. Is the error message is disappeared?
2) If the problem persists, turn the machine off and remove the fuser unit.
a) Check if the fuser connector is connected properly.
b) Check if the input voltage is normal.
c) Check if the thermistor is twisted or contaminated; and is in contact with the Heat Roller.
3) After confirming continuity in the fuser connector and the problem still exists; order an SMPS and Fuser Unit
and install as is necessary.
4-66
Copyright© 1995-2017 SAMSUNG. All rights reserved.