4. Troubleshooting
4.7.2.2. Ax-xxxx (Motor_Fan_Sensor error)
► Error Code
A1–1112
A1–1113
► Error message
Error: #A1-1112 / Motor Failure: #A1-1112. Turn off then on. Call for service if the problem persists
Error: #A1-1113 / Motor Failure: #A1-1113. Turn off then on. Call for service if the problem persists
► Symptom
Main (OPC) motor operation is abnormal.
► Troubleshooting method
•
A1–1112 : Main motor is not operated for print-job.
•
A1–1113 : Main motor is operating but machine recognizes status as "Stopped".
1) Turn the machine off then on. If the error persists, check the following.
2) Remove the side cover.
3) Check the connection between the main motor and main board.
4) If the connection is OK, enter SVC mode. Execute the motor test.
(Diagnostics > Engine Diagnostics > Engine Test Routines)
a) If the motor is not operational,
i) Check the motor signal(3.3V). If the signal is abnormal, replace the main board.
ii) Check the power(24V). If the power is abnormal, check the SMPS board. If the SMPS board is defective,
replace it.
iii) If the motor signal and power is normal, replace the main motor or main drive unit.
b) If the motor is operational, replace the main board.
4-38
Copyright© 1995-2017 SAMSUNG. All rights reserved.