OfficeServ 500 Wireless LAN Service Manual/Ed.00
CHAPTER 4. MMC Programming
© SAMSUNG Electronics Co., Ltd.
Page 4-15
Number
Parameters
Description
08 REMOTE
M/A
ADDR
When system wants connect to remote M & A PC, system will be send
to this IP address for connection message. Reserved for future use.
Changing IP address/value
When changing any IP address/value, listed below, three digits must be input for
each(octet) field.
Example) 192.168.1.10 input must be : 192 168 001 010
The first 3 parameters
SYSTEM IP address, system gateway, and system net mask are stored separate
from the main system database, thus will not be defaulted when MMC811 ‘CLEAR
MEMORY’ is performed. Furthermore, any changes to these parameters will not be
applied until the MCP2 is reset.
Program Buttons
VOLUME
Used to scroll through options
KEYPAD
Used to enter selections
SOFT BUTTONS Move cursor left and right
SPEAKER
Used to advance next MMC
Action
DISPLAY
1) Press Transfer button and enter 830
Display shows the system IP address.
2) Press Volume button to make selection and
Press Right Soft button to move cursor.
3) Using the keypad enter three digit IP octet
numbers IE 192 168 001 010 for 192.168.1.10
Cursor will return to Step 1 upon completion
of IP address entry.
4) Press Volume button to make selection and
Press Right Soft button to move cursor.
U
S
U
YSTEM IP ADDR
165.213. 97.185
SYSTEM IP ADDR
U
1
U
65.213. 97.185
SYSTEM IP ADDR
192.168.001.01
U
0
U
S
U
YSTEM GATEWAY
165.213. 97. 1