CHAPTER 7. Connecting Optional Equipment
7-10
© SAMSUNG Electronics Co., Ltd.
7.7 Remote Programming
Use MISC 1 (2): DCS Compact-II or iDCS 100 System
To remotely program a system, connect a customer-provided Local external modem to a
serial interface connector on a MISC 1(2) card(See Figure 7.8).
MISC, MEM4 Card
Modem
TX 2
RX 3
DTR 4
GND 5
RTS 7
CTS 8
2
3
20
7
4
5
TX
RX
DTR
GND
RTS
CTS
Figure 7.8 PIN Connections for MISC Card to MODEM
Use an RS232C cable as shown in Figure 7.8. When the modem needs to be more than 15
feet away from the KSU, use shielded computer cable. Attach a male DB9 connector to the
MISC 1(2) end and then attach one that matches the requirements of the modem to the
other end. This cable must not exceed 300 feet.
Use MMC 804 to set the transmission parameters and the MISC port to be used.
Use MCP1 or OfficeServ 100 System
The OfficeServ 100 can be remote programmed with a PC equipped connected to the
MCP1 LAN port or via serial interface of the MCP1.
7.8 PFT (Power Failure Transfer)
When the system loses AC power and have no external battery, the first two loop start lines
in 3/6 TRK card are automatically switched to the PFT ports. Directly connect these
outputs to any SLI valid ports.
Содержание OFFICESERV 100 Series
Страница 1: ...GABD 000100 Ed 00 OfficeServ 100 Installation Manual 10 2004 ...
Страница 6: ...INTRODUCTION IV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Страница 54: ...CHAPTER 4 Power Up Procedures 4 4 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Страница 62: ...CHAPTER 5 Connecting Trunk Line Circuit 5 8 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Страница 88: ...CHAPTER 7 Connecting Optional Equipment 7 12 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...