CHAPTER 6. Connecting Station Equipment
6-8
© SAMSUNG Electronics Co., Ltd.
25 PAIR CABLE WITH FEMALE CONNECTOR TO BASIC P1
6.4 Door Phone and Door Lock Release
Using one pair twisted #24 AWG or #26 AWG wire, cross-connect each DPIM to the DLI
port of your choice(See Figures 6.7 and 6.8). Next, connect the DPIM(Door Phone
Interface Module) to the door phone using #24 AWG or #26 AWG twisted pair wire.
PIN
COLOR
CIRCUIT
FUNCTION
25
50
Grey/purple
Purple/grey
1
DLI TIP
DLI RING
24
49
Brown/purple
Purple/brown
2
DLI TIP
DLI RING
23
48
Green/purple
Purple/green
3
DLI TIP
DLI RING
22
47
Orange/purple
Purple/orange
4
DLI TIP
DLI RING
21
46
Blue/purple
Purple/blue
5
DLI TIP
DLI RING
20
45
Grey/yellow
Yellow/grey
6
DLI TIP
DLI RING
19
44
Brown/yellow
Yellow/brown
7
DLI TIP
DLI RING
18
43
Green/yellow
Yellow/green
8
DLI TIP
DLI RING
Figure 6.7 MDF Connections Door Phone to Basic KSU P1
CONNECT TO ANY DLI CIRCUIT
DOOR PHONE
ONE PAIR TWISTED
SHEATHED STATION
CABLE 24 OR 26 AWG
TO CUSTOMER-PROVIDED
DOOR LOCK RELEASE
THREE PAIR
MODULAR CABLE
DOOR PHONE
INTERFACE
MODULE(DPIM)
TWO PAIR
MODULAR
CABLE
Содержание OFFICESERV 100 Series
Страница 1: ...GABD 000100 Ed 00 OfficeServ 100 Installation Manual 10 2004 ...
Страница 6: ...INTRODUCTION IV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Страница 54: ...CHAPTER 4 Power Up Procedures 4 4 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Страница 62: ...CHAPTER 5 Connecting Trunk Line Circuit 5 8 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Страница 88: ...CHAPTER 7 Connecting Optional Equipment 7 12 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...