CHAPTER 7. Connecting Optional Equipment
7-4
© SAMSUNG Electronics Co., Ltd.
25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1
Basic provide 1 zone control relays and If installed, the MISC card provides three zone
control relays(See Figure 7.3). These paging contact pairs are for control of low voltage
circuits or amplifier output. The contacts are rated at 24 VDC-1 amp.
PIN
COLOR
TERM
CIRCUIT
FUNCTION
11
36
Blue/black
Black/blue
1
OPEN A
OPEN B
10
35
Grey/red
Red/Grey
BGM 1A
BGM 1B
9
34
Brown/red
Red/brown
1
BGM 2A
BGM 2B
8
33
Green/red
Red/green
PAGE 1A
PAGE 1B
7
32
Orange/red
Red/orange
2
PAGE 2A
PAGE 2B
5
30
Grey/white
White/grey
3
TACT 1A
TACT 1B
4
29
Brown/white
White/brown
4
TACT 2A
TACT 2B
3
28
Green/white
White/green
TACT 3A
TACT 3B
2
27
Orange/white
White/orange
ALARM 1
ALARM 2
Figure 7.3 MDF Connections Connecting Page Amplifier to KSU
Commercial
AC
Power
Do not attempt to connect commercial AC power to the contacts on the External
Paging.
NOTE: THE TACT RELAYS REQUIRE A MISC CARD
CUSTOMER-PROVIDED
PAGING AMPLIFIER
ZONE 1
ZONE 2
ZONE 3
ZONE 4
IN
OUT
Содержание OFFICESERV 100 Series
Страница 1: ...GABD 000100 Ed 00 OfficeServ 100 Installation Manual 10 2004 ...
Страница 6: ...INTRODUCTION IV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Страница 54: ...CHAPTER 4 Power Up Procedures 4 4 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Страница 62: ...CHAPTER 5 Connecting Trunk Line Circuit 5 8 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Страница 88: ...CHAPTER 7 Connecting Optional Equipment 7 12 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...