8 English
Ins
tallation
A
B
C
D
E
Built-in cabinet (mm)
A
Min. 550
B
Min. 560
C
Min. 50
D
Min. 590 - Max. 600
E
Min 460 x Min. 50
NOTE
The built-in cabinet must have vents
(E)
to
ventilate heat and circulate the air.
B
C
A
D
Under-sink cabinet (mm)
A
Min. 550
B
Min. 560
C
Min. 600
D
Min 460 x Min. 50
NOTE
The built-in cabinet must have vents
(D)
to
ventilate heat and circulate the air.
Cabinet mount
If installing the oven in a built-in cabinet, the cabinet must have its plastic surfaces
and adhesive parts resistant to temperatures in accordance to EN 60335. Samsung
is not responsible for damage to furniture from the oven’s heat emission.
The oven must be properly ventilated. For ventilation, leave a gap of about 50 mm
between the lower shelf of the cabinet and the supporting wall. If you install the
oven under a cooktop, follow the cooktop’s installation instructions.
Required Dimensions for Installation
A
B
C
D
E
G
F
H
I
J
L
K
Oven (mm)
A
560
G
Max. 506
B
175
H
Max. 494
C
370
I
21
D
Max. 50
J
549
E
595
K
572
F
595
L
550
Installation
NV73N9770RM_EE_DG68-00NO+FI+DA+EN.indb 8
NV73N9770RM_EE_DG68-00NO+FI+DA+EN.indb 8
2021-06-08 오후 3:58:06
2021-06-08 오후 3:58:06