English 23
Installation instructions
Supplied parts
The following parts make up the LP conversion kit:
NA30*5310F*
NA36*5310F*
The all orifices’ positions are marked on the provided sheet. The spud in the
pressure regulator is factory-installed for Natural Gas (NG) use. LP conversion
requires spud removal and reinstallation for LP use.
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner Location
BTU Rate
Orifice size [mm]
RF ¹
12500
1.06
RF ²
11500
1.04
LF ¹
11500
1.04
LF ²
8000
0.83
RR
4500
0.62
LR
8000
0.83
Center ²
12500
1.06
1
Model NA30*5310F*
2
Model NA36*5310F*
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner Location
BTU Rate
Orifice size [mm]
RF ¹
17000
1.92
RF ²
13000
1.64
LF ¹
13000
1.64
LF ²
10000
1.4
RR
5000
1.01
LR
10000
1.4
Center ²
17000
1.92
1
Model NA30*5310F*
2
Model NA36*5310F*
NOTE
115
Orifice markings:
115 – Denotes 1.15 mm orifice size opening.
Install_NA30R5310FG_AA_DG68-01133A-00_EN.indd 23
2019-04-12 12:13:38