24 English
Installation instructions
Installation instructions
Required tools
Adjustable wrench
1
/
2
” open-end wrench
Screwdrivers: Phillips
Small flat-bladed
precision screwdriver
Nut drivers:
9
/
32
” or
7 mm
To convert your for use with LP gas, perform the following steps and procedures:
1.
Disconnect electrical power to the cooktop.
Unplug the cooktop power cord, trip
the circuit breaker, or remove the fuse from the fuse box.
2.
Shut off the gas supply to the cooktop.
Close the manual shut-off valve to the
cooktop.
Converting the pressure regulator
NOTE
If you are using LP gas to fuel the cooktop, the following steps and conversions
must be made before the flames can be adjusted.
1.
Using your fingers, turn the cap. And carefully look at the spring retainer to
locate the NAT or LP position.
LP
LP
LP
LP
NAT
NAT
NAT
NAT. Position
L.P./Propane
Position
Pressure Regulator
Spring
Retainer
NAT
Cap
Gasket
2.
Turn the spring retainer over by rotating it 90 deg., pull it from the cap, turn the
spring retainer over so that LP is showing, insert it back into the cap, and then
rotate it 90 deg. Into position.
3.
Screw the cap back onto the regulator and tighten.
Install_NA30R5310FG_AA_DG68-01133A-00_EN.indd 24
2019-04-12 12:13:38