English 25
Installation instructions
NOTE
Save these orifices and note their positions for future conversions back to natural
gas.
3.
Locate the LP conversion orifices that were shipped with the cooktop.
4.
Identify the proper orifice by orifice size for each of the cooktop burners.
5.
Install the proper orifices in each of the burner manifold cups and tighten with
a
9
/
32
” or 7 mm nut driver.
NOTE
Any other placement of orifices could result in dangerous operating conditions
and/or poor cooking results.
6.
Set all burner heads on top of the manifold cups in the same location as
they were removed. The hole on the side of the burner heads goes over the
electrodes. The burner heads are correctly installed when they are flat on the
top of the manifold cups.
7.
Set all burner caps on top of the burner heads. These are also flat when they are
installed to ensure proper safe operation.
Converting the cooktop burners
NOTE
If you are using LP gas to fuel the cooktop, the following steps and conversions
must be made before the flames can be adjusted.
1.
Lift off the cooktop burner caps and the cooktop burner heads from the cooktop
burner manifold cups.
Cap
Burner Head
Burner Cup
Cooktop Burner Locations
2.
Using a
9
/
32
” or 7 mm nut driver, remove the burner orifice from the bottom of
each burner manifold cup.
Cooktop
Burner Orifice
Install_NA30R5310FG_AA_DG68-01133A-00_EN.indd 25
2019-04-12 12:13:38