Wired Remote Controller Installation
3.
Using more than two screws, firmly affix the rear cover of the remote controller to the wall, and then connect the
power(V1, V2) and communication cables(F3, F4), making sure these cables have reasonable length, to the terminal at
the back of the cover.
10mm (0.4 inch) or more
10mm (0.4 inch)
or more
50mm (2 inch) or more
10mm (0.4 inch) or more
Rear cover
Screw hole
Wire (not supplied)
PCB terminal
Front cover
Wired remote
controller
Hydro Unit
Hydro Unit
PCB
❋
Before fixing the rear cover, allow
at least 10mm(0.4 inch) space of
upper side, left side, right side, and
50mm(2inch) space of bottom side.
❋
You must fit the screws into the
screw holes.
❋
Do not tighten the screws on the
PCB terminal with excessive force.
4.
Reassemble your wired remote controller.
•
Align the controller with the upper groove first, and insert it by turning it downward as shown in the
figure. After assembly, check and confirm that no wires are stuck in the gap between the rear and
front cover.