Specification table
Part
Specification
Tab-Terminal (output)
Step1 : CNP003, CNP001
Step2 : CNP003, CNP002
Connection load
Relay or Magnetic contactor for a control signal
Output(CNP003,CNP001 or
(CNP003,(CNP003,CNP002)
AC 230V (MAX 0 .5A)
Backup boiler
Connection of the back-up boiler
Description
No. of wires
Max. A
Thickness
Supply Scope
Back-up Boiler
2+ground
10 mA
0 .75mm
2
H05RN-F or
H07RN-F
Field supply (230 V~,
Input)
L N
L N
When it set back up
boiler on the control kit
(relay off )
Boiler
Back up boiler (L)
Back up boiler (N)
Boiler
When it order to back up
boiler operates (relay on)
B4
B5
1 . Before the installation, control kit should be turned off .
2 . Using the appropriate equipment to correct position of terminal
block as shown on the diagram .
3 . Make sure EXT-CTRL signal of back up boiler must be 230Vac .
- Do not connect supply power of back up boiler directly .
❋
❋
Heat pump does not work when the Back-up boiler operates .