Connecting the communication wire
f
f
Connect ‘outdoor unit’s F1&F2’ with ‘control kit’s F1&F2 in TB-C’ by 2 core cable .
Outdoor Unit
(at Control Plate)
Control Kit
Communication with a wired remote controller (1 unit)
Wired Remote Controller
(Master)
Communication with a wired remote controller (2 units)
Wired Remote Controller
(Slave)
Wired Remote Controller
(Master)
Connecting a wired remote controller
1 . Connect 'F3, F4' of TB-C kit with 'F3, F4' of a wired remote controller .
f
f
2 units (wired remote controllers) are able to be installed on TB-C .
f
f
When 2 units are installed, either one shall has "Master" setting and another one shall have "Slave" settings on a wired
remote controller .
15
ENGLISH
EHS MONO Kit-EU_IM_05388A-00_EN.indd 15
2015-03-18 오전 11:53:38