Wiring works
Power and communication with outdoor unit
Power Wire
ELCB
Communication
Wire
N
L
•
Be careful when connecting L, N .
CAUTION
Connecting the power wire
1 . Connect ‘Live’ and 'Neutral’ power line with ‘L, N’ of a ELCB .
2 . Connect ‘L,N’ of a ELCB with ‘A1 and A2’ in TB-A .
3 . Connect ‘Protective Earth’ line with ‘Earth screw’ In case .
Recommended wire specification
Load
Power Supply
Power Cable
Max. Length
mm
2
, wires
m
Do NOT use Heater (Water Pump,
Valve, Wired RMC)
1Ø, 220-240V, 50Hz
1 .5 / 3
L < 10m
2 .5 / 3
10m < L
Use Booster Heater (Max. 3kW)
4 .0 / 3
L < 10m
6 .0 / 3
10m < L
f
f
The power cable is not supplied with Air to water heat pump .
f
f
This equipment with "IEC 61000-3-12" .
f
f
Supply cords of parts of appliances for control kit use shall not be lighter than polychloroprene sheathed flexible cord
(Code designation IEC:60245 IEC 57 / CENELEC:H05RN-F)