Testing Steam Cycle:
Select Wrinkle Care cycle for 4 minutes, check for heat and moisture. If both are present, the dryer is working properly
Major Dryer Spray
Components
Gas Valve Testing
Unplug connectors and test valve terminals
(its numbering is from the front terminal.)
Check across terminals #1 and #3 (Booster Coil). 550
Ω
Check across terminals #1 and #2 (Holding Coil). 1350
Ω
Check across terminals #2 and #3 (Both coils in series).1900
Ω
Check across terminals #4 and #5 (Secondary Coil). 1300
Ω