Testing Main PCB power 

output to Heating 

& Motor circuit. 

With motor running in the heating mode, 
read AC voltage across RY6 and RY1. 

Any voltage reading means Main PCB is  
defective. 

See page 4 for Main PCB layout for testing.

 

Testing Motor circuit. 

With power off read 
resistance between 
RY1 Brown and CN7 
Blue. 

Resistance reading of 
good motor circuit is 
about 1.9

. To test 

thermostat and switch 
use ohm meter on      
lowest scale, any            
resistance replace 
component. 

See page 4 for Main 
PCB layout for testing.

 