background image

5

ENGLISH

FOR USING

WARNING

Do not place an object near the outdoor unit that allows children to climb onto the machine.

  This may result in children seriously injuring themselves. 

  Since this may be dangerous due to a lack of oxygen, Open a window at least once an hour. 

If any foreign substance such as water has entered the appliance, cut the power by unplugging the power plug and 

  Failing to do so may result in electric shock or fire.

Do not attempt to repair, disassemble, or modify the appliance yourself.

  Do not use any fuse (such as cooper, steel wire, etc.)other than the standard fuse. 

  Failing to do so may result in electric shock, fire, problems with the product, or injury.

FOR USING

CAUTION

Do not place objects or devices under the indoor unit.

  Water dripping from the indoor unit may result in fire or property damage.

Check that the installation frame of the outdoor unit is not broken at least once a year.

  Failing to do so may result in injury, death or property damage.

Max current is measured according to IEC standard for safety and current is measured according to ISO standard for 

Do not stand on top of the appliance or place objects (such as laundry, lighted candles, lighted cigarettes, dishes, 

chemicals, metal objects, etc.) on the appliance.

  This may result in electric shock, fire, problems with the product, or injury.

Do not operate the appliance with wet hands.

  This may result in electric shock.

Do not spray volatile material such as insecticide onto the surface of the appliance.

  As well as being harmful to humans, it may also result in electric shock, fire or problems with the product.

Do not drink the water from the air conditioner.

  The water may be harmful to humans.

Do not apply a strong impact to the remote controller and do not disassemble the remote controller.

Do not touch the pipes connected with the product.

  This may result in burns or injury.

Do not use this air conditioner to preserve precision equipment, food, animals, plants or cosmetics, or for any other 

unusual purposes.

  This may result in property damage.

  This may result in harm to humans, animals or plants.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use 

of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play 

with the appliance. 

FOR CLEANING

WARNING

Do not clean the appliance by spraying water directly onto it. Do not use benzene, thinner or alcohol to clean the 

appliance.

  This may result in discoloration, deformation, damage, electric shock or fire.

Before cleaning or performing maintenance, unplug the air conditioner from the wall socket and wait until the fan stops. 

  Failing to do so may result in electric shock or fire.

FOR CLEANING

CAUTION

Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges.

  To avoid cutting your fingers, wear thick cotton gloves when cleaning it.

Do not clean the inside of the air conditioner by yourself.

  For cleaning inside the appliance, contact your nearest service center.

  When cleaning the internal filter, refer to the descriptions in the ‘Cleaning the air conditioner’ section.

  Failure to do may result in damage, electric shock or fire.

MAX_XSA_IBIM_DB98-33747A_E.pdf

Содержание AQV09USeries

Страница 1: ...Air Conditioner user installation manual imaginethe possibilities ThankyouforpurchasingthisSamsungproduct To receive more complete service please register your product at www samsung com register DB98...

Страница 2: ...nstallation plate 26 Connecting the assembly cable 27 Installing and connecting the assembly pipe ofthe indoor unit 29 Purging the indoor unit 30 Cutting or extending the pipe 30 Installing and connec...

Страница 3: ...unlight and water rain drops Do not installthis appliance in a location where gas may leak This may result inelectric shock or fire Never install the outdoor unit in a location suchas on a high extern...

Страница 4: ...o do so may result in electric shock or fire In the event of a gas leak such as propane gas LP gas etc ventilate immediately without touching the power plug Do not touch the appliance or power cord Do...

Страница 5: ...e product Do not drink the water from the air conditioner The water may be harmful to humans Do not apply a strong impact to the remote controller and do not disassemble the remote controller Do not t...

Страница 6: ...C 24 C 32 C Relative humidity 80 or less AQV09 12U AQV18U AQV09 12U AQV18U AQV09 12U AQV18U Heating 27 C or less Dry 16 C 10 C 46 C 32 C Internal protections via the unit control system This internal...

Страница 7: ...ENGLISH 7 Main parts Display Checking the nameof the parts MAX_XSA_IBIM_DB98 33747A_E pdf Air intake up and down Room temperature sensor Timer Auto Clean indic SPi indicator ator...

Страница 8: ...ndoor unit during operation Power Mode Set one of the 5 operating modes see pages 10 11 for instructions Auto Clean Auto clean function Dry inside of the indoor unit to get rid of odor Temp hr Increas...

Страница 9: ...this product Applicable in the European Union and other European countries with separate battery return systems This marking on the battery manual or packaging indicates that the batteries in this pr...

Страница 10: ...air conditioner will cool your room You can adjust the temperature and the fan speed to feel cooler in hot season If current outside temperatures are much higher than the selected indoor temperature...

Страница 11: ...d High Press the button to adjust thetemperature Auto You can adjust the desired temperature by 1 C within the range of 16 C 30 C Cool You can adjust the desired temperature by 1 C within the range of...

Страница 12: ...sition you prefer There is a potential risk of personal injury when the unit is mishandled Using theTurbo function e d o m l o o C n i e l b a l i a v a y l n o s i n o i t c n u f o b r u T e h t s s...

Страница 13: ...de is set less than 4 hours the operation will stop at the same time If the mode is set over 5 hours it will run asWake up stage from the last one hour before it stops g n i t a e h r o f C 3 2 C 1 2...

Страница 14: ...utton for hour andFanmin button for minute 3 PressTimeSetbutton again to active it 1 Press the button O 2 Press theTemphr or button andFanmin button to set the time You can set the time in hourly unit...

Страница 15: ...he temperature range limit to help you save energy while the air conditioner is operating in Cool mode PresstheSmartSaverbutton on the remote controllerwhile the air conditioneris operating in Cool mo...

Страница 16: ...mately 15 minutes Using theQuiet function You can reduce the noise generated from an indoor unit PresstheQuiet button on theremote controllerwhilethe air conditioneris operating in Cool Heat mode Quie...

Страница 17: ...lean the display using alkaline detergent Do not use sulfuric acid hydrochloric acid organic solvents such as thinner kerosene and acetone etc to clean the surface of the product or put any stickers o...

Страница 18: ...original position and close the front panel Dry theAi lter in aventilated area CleantheA ter with a vacuum cleaneror soft brush If dust istoo heavy rinse it with running water o n the usage and envir...

Страница 19: ...the air conditioner properly Type Description Every2 weeks Every3 months Every4 months Onceayear Indoor unit 1 Clean the condensate drain pan 2 Thoroughly clean the heat exchanger 2 Clean the condens...

Страница 20: ...dows Check if the air conditioner has just been turned on after stopping cooling heating operation In this case just a fan will run to protect the outdoor unit compressor Check if the pipe length is t...

Страница 21: ...nts set forth in the Operating limits table included in the manual shall immediately invalidate the warranty The air conditioner should be used only for the applications for which it has been designed...

Страница 22: ...units components must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason where it is not observed as indicated into the Installatio...

Страница 23: ...conditioner Avoid the g places to prevent malfunction of the unit Where there is machine oil Salty environment such as seaside areas Other special atmosphere areas 125mm or more 300mm or more 125mm or...

Страница 24: ...0 or more 300 or more The upper part of the outdoor unit and the air outlet is opposite the wall When the walls are blocking front and the rear side of the outdoor unit 300 or more 1500 or more Top vi...

Страница 25: ...vibration will not cause any Accessories The following accessories are supplied with the air conditioner The number of each accessory is indicated in parentheses Accessories inthe indoor unit case Acc...

Страница 26: ...le can be connected from the Right A Left B Underside_right C Rear_right or left D B A D C D Direction of pipe 1 Determine the position of the pipe and drain hose hole as seenin the picture and drill...

Страница 27: ...f you install the product in a place where it is not strong enough to withstand the product weight the unit could fall and cause injury Connecting the assembly cable When you install the unit make ref...

Страница 28: ...t g n i d n o p s e r r o c e h t h t i w d e l e b a l s i e r i w h c a E Indoor unit Outdoor unit 09 12 18 Indoor unit Outdoor unit Ground wire Green Yellow Ground wire Green Yellow End of the wire...

Страница 29: ...t pressure of at least 20700 kPa Under no circumstances must sanitary type copper pipe be used There are 2 refrigerantpipes of diameters The smaller one is for the liquid refrigerant The larger one is...

Страница 30: ...pe longer than 5 meters You must extend the assembly cable You must add refrigerantto the pipes otherwise the indoor unit may freeze Unscrew the caps Pipes Oblique Rough Burr Pipe cutter Pipe The rema...

Страница 31: ...ollow Ditch 5 6 applying the following torque 7 For further details on how to connect to the outdoor unit and purge the air refer to page 33 35 Correct Uneven Thickness Cracked Damaged Surface Incline...

Страница 32: ...bber capwith the plier 2 Detach the drain hoseby pulling it and turning to the left 3 hose and the outlet of the drain pan 4 Attach the rubber cap witha screwdriver by turning it to the right until it...

Страница 33: ...bottom surface of the outdoor unit In areas with heavy snow fall piled snow could block the air intake To avoid this incident install a frame that is higher than estimated snow fall In addition instal...

Страница 34: ...ce port capto thevalve and tighten themat the torque of 183kgf cmwith a torque wrench 8 Checkfor a gas leak paying particularattention to the 3 way valve s stem nuts and to the service port cap Refer...

Страница 35: ...egarding the refrigerant used Charging the refrigerant under conditions of liquid by usinga liquid pipe a Factory refrigerantcharge of the product see unit name plate b to the above information for th...

Страница 36: ...rding to page 33 35 After opening valves check leaks using a leak detector for refrigerant Pump down before disconnecting therefrigerant connections for unit repair removal or disposal Pump down is an...

Страница 37: ...et thedischarged air out properly 2 Fix theoutdoor unit in level to an appropriate support using anchor bolts 3 If the outdoor unit is exposed to strongwinds install shield plates around the outdoor u...

Страница 38: ...p operation of the air conditioner 6 Disconnect the pipes 3 PresstheAirswing button and checkthefollowing 4 PressthePower button to stop the operation 2 PresstheMode button to select Cool or Heat mode...

Страница 39: ...5 Apply heat to the contraction tube to contract it 6 After tubecontraction work is completed wrap it with the How to connect your extended power cables Tools Crimping plier Connectionsleeve mm Insula...

Страница 40: ...QUESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT AUSTRALIA 1300 362 603 www samsung com MAX_XSA_IBIM_DB98 33747A_E pdf...