ENGLISH
19
Maintaining the air conditioner
If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition.
1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug.
There may be internal damage if moisture is left in components.
2. Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode
for 3 to 4 hours. This helps remove odors which may have generated from dampness.
Periodical checks
Refer to the following chart to maintain the air conditioner properly.
Type
Description
Every 2
weeks
Every 3
months
Every 4
months
Once a year
Indoor
unit
(1)
Clean the condensate drain pan (2)
Thoroughly clean the heat exchanger (2)
Clean the condensate drain pipe (2)
Replace the remote controller batteries (1)
Outdoor
unit
Clean the heat exchanger on the outside of the unit (2)
Clean the heat exchanger on the inside of the unit (2)
Clean the electric components with jets of air (2)
tightened (2)
Clean the fan (2)
Clean the condensate drain pan (2)
: This check mark requires checking the indoor/outdoor unit periodically, following to the description to maintain the
air conditioner properly.
(1) The described operations should be performed more frequently if the area of installation is very dusty.
(2)
installation part in the manual.
MAX_XSA_IBIM_DB98-33747A_E.pdf