background image

www.larius.com

19

GIOTTO FOR SANITATION

REV. 01 - 04/2020 - Cod. 150113

Pos.

Code

Description

1*

12455

Hydraulic support

2

12456

Hydraulic piston

3

82019G Spring  pad

4

82021

Spring

5*

82017

Cylinder liner

6

82022

O-Ring

7

82023

Spring housing

8

82024

Elastic ring

9*

31125

Bearing

10*

81020

Elastic ring

11

12457

Bearing

12

12467

Elastic ring

13

12466

Elastic ring

14

12465

Bearing

15

12464

O-Ring

16

12459

Cover

17

12462

PTFE Washer

18

901568 Screw

19

31128

Gas-ring

20

12490

Pulley assembly

21

81038

Shock absorber

22

12460

Half-joint

23

81019

Dowel

24

81012

Spline

Pos.

Code

Description

1

12455

Hydraulic support

5

82017

Cylinder liner

9

31125

Bearing

10

81020

Elastic ring

Pos.

Code

Description

25

81014

Key 

26

81033

Washer

27

95158

Nut

28

32007

Oil level plug

29

32006

Plug

30

32012

O-Ring

31

258

Filter

32

32010

Washer

33

12461

Oil filter body

34

12475

Oil filter screw

35

32017/1C Dowel

36

32017/1 Knob

37

32017/2 Spring

38

32155

Safety catch

39

32014

Valve body

40

32150

O-Ring

41

81001

Pressure regulation

41

81003

Electric motor 230V 50HZ

42

3637

Electric motor 110V 60Hz

43

52019

Plug

44

5598

Label

45

81045

Identification plate 

46

34021

Rivets

* SPARE SUPPLIED COMPLETE (RECOMMENDED) - RIF. 12488

Содержание LARIUS GIOTTO

Страница 1: ...04 2020 Manuale Cod 150113 GIOTTO FOR SANITATION OPERATING INSTRUCTIONS Giotto 220 V Code SE9020 Giotto 110 V Code SE9021 Giotto 220 V with gravity hopper 50 Lt Code SE9022 Giotto 110 V with gravity h...

Страница 2: ...ear no responsibility for any damages or inconveniences that may arise due to the incorrect translation of the instructions contained within the original manual in Italian Due to a constant product im...

Страница 3: ...or sanitation A C D B E H G F I M N J K L O P Q R S T U V WARNINGS p 4 USE p 5 WORKING PRINCIPLE p 6 TECHNICAL DATA p 6 DESCRIPTION OF THE EQUIPMENT p 7 TRANSPORT AND UNPACKING p 9 CONDITIONS OF GUARA...

Страница 4: ...uipment carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has...

Страница 5: ...quid flammable USE SANITIZING PRODUCTS SPRAYING EQUIPMENT The spraying of liquids under high pressure allows you covering large surfaces with sanitizing agents thus reducing the presence of bacteria f...

Страница 6: ...pump An electric diaphragm pump is used for high pressure spraying without air known as airless The pump is powered by an electric motor coupled with a cam shaft The shaft acts on the hydraulic pisto...

Страница 7: ...eter 4 Setting valve 5 Hydraulic oil filling cap Pos Description 6 Hydraulic body 7 Recirculation Open Close valve 8 Recirculation pipe delivery connection 9 Recirculation tube 10 Product suction tube...

Страница 8: ...9 Recirculation tube 11 Product delivery pipe connection 12 Power supply cable Pos Description 13 PVC tank 50 Lt 14 ON OFF switch of the equipment Gravity hopper version 50 Lt The machine is supplied...

Страница 9: ...and cleaning of components causing malfunction wear or damage to the equipment or any of its parts improper use of the equipment use that does not conform with applicable na tional legislation incorr...

Страница 10: ...the equipment The pump is earthed through the earth cable of the supply The gun is earthed through the high pressure flexible hose All the conductors near the work area must be earthed Always check th...

Страница 11: ...h a maximum length of 50 mt Higher lengths and lower dia meters can provoke excessive voltage falls and also an anomalous working of the equipment CONNECTION OF THE TOOLING TO THE POWER SUPPLY Check t...

Страница 12: ...come into contact with aluminium parts of the equipment can provoke dangerous chemical reactions with risk of explosion WASHING OF THE NEW EQUIPMENT Theequipmenthasalreadybeenadjustedatourfactorywith...

Страница 13: ...nob J3 clockwise so as the machine works at the idle speed Make sure the product recycles from the return tube J4 Close the re circulation valve At this point the machine will continue to suck the pai...

Страница 14: ...switch K2 on the ON position and rotate the pressure setting knob K1 slightly clockwise Make sure the solvent recycles the washing fluid from the return tube CLEANING AT THE END WORK Reduce pressure...

Страница 15: ...Then substitute the oil every 250 hours CLEANING THE MOTOR COOLING FAN GUARD Clean the motor cooling fan protection guard periodically to ensure the best cooling ROUTINE MAINTENANCE TOP UP HYDRAULIC...

Страница 16: ...pressure desired Lack of product Add the product The equipment sucks air Check the suction pipe The drain valve is open Close the drain valve Suction or delivery valve dirty Disassemble the colour bo...

Страница 17: ...etriggertoreleasepressure Attheend of the operation insert the gun clamp Openthere circulationvalve O5 toreleaseresidualpressure If the equipment is still under pressure after performing the operation...

Страница 18: ...18 GIOTTO FOR SANITATION REV 01 04 2020 Cod 150113 35 37 38 39 10 11 12 13 14 15 17 18 34 40 30 31 32 16 33 1 43 28 19 9 Rif 12488 2 3 4 5 6 7 8 36 26 27 44 46 45 36 20 21 22 25 41 42 23 24 P COMPLETE...

Страница 19: ...ck absorber 22 12460 Half joint 23 81019 Dowel 24 81012 Spline Pos Code Description 1 12455 Hydraulic support 5 82017 Cylinder liner 9 31125 Bearing 10 81020 Elastic ring Pos Code Description 25 81014...

Страница 20: ...www larius com 20 GIOTTO FOR SANITATION REV 01 04 2020 Cod 150113 23 24 25 26 27 28 29 30 20 19 18 17 16 21 22 13 14 15 12 11 10 31 8 7 6 5 4 3 2 1 9 Q COMPLETE COLOUR BODY...

Страница 21: ...lve 10 83004 Screw 11 33005 Washer 12 83001 Colour body fusion 13 83003 Diaphragm insert 14 33007 Washer 15 3199 Feed tube union 16 83002 1 Diaphragm Pos Code Description 17 83002 2 Oil distributor 18...

Страница 22: ...d 150113 1 2 6 5 4 3 R Pos Code Description 1 81001 Electric motor 220V 50HZ 1 81003 Electric motor 110V 60Hz 2 86003 Electic box 3 86001 Condenser 220V Pos Code Description 3 86004 Condenser 110V 4 8...

Страница 23: ...2020 Cod 150113 S 6 5 3 4 8 7 1 2 Pos Code Description 1 12454 Foot 2 12710 Trolley base 3 37218 Pneumatic wheel 4 91047 Elastic washer Pos Code Description 5 84007 Split pin 6 12711 Trolley handle 7...

Страница 24: ...www larius com 24 GIOTTO FOR SANITATION REV 01 04 2020 Cod 150113 T 425 548 17 16 19 18 16 GRAVITY HOPPER 50L GIOTTO RIF 18240...

Страница 25: ...Filter 3 18231 Gun extension filter 4 18249 Gravity hopper 50 L 5 20833 Elbow 6 20817 Junction 7 20825 Cock 8 96098 Junction 9 96099 Gas ring 10 18224 Recirculation tube Pos Code Description 11 18223...

Страница 26: ...for 30 lt drums Code 3350 1 Suction tube for 200 lt drums Code SE9041 Suction tube for 1000 lt drums Code 18024 Length 15 m Code 18024 20 Length 20 m Code 18024 25 Length 25 m Code 18024 30 Length 30...

Страница 27: ...NOTE the filter choice depends on the type of machine and of the product to be sprayed Code 155 Length 60 cm Code 156 Length 100 cm Code SE9060 Length 130 cm Nozzle SFC 13 60 Code SE9061 Length 180 cm...

Страница 28: ...zle angle inch mm Filter recom SFC07 20 0 007 0 18 Red 200 M SFC07 40 SFC09 20 0 009 0 23 SFC09 40 Yellow 100 M SFC11 20 0 011 0 28 SFC11 40 SFC13 20 0 013 0 33 SFC13 40 SFC13 60 SFC15 20 0 015 0 38 S...

Страница 29: ...NITATION REV 01 04 2020 Cod 150113 V GHIBLI Cod SE9000 ZEUS Cod SE9010 110V Cod SE9011 220V Cod SE9012 Petrol DAL Cod SE9030 with hose reel 50 Lt Cod SE9031 with hose reel 30 Lt Cod SE9032 50 Lt Cod S...

Страница 30: ...I n t e n t i o n a l l y b l a n k p a g e...

Страница 31: ...ctive 2014 35 Low Voltage LVD nonch alle seguenti norme armonizzate furthermore to the harmonized standards UNI EN ISO 12100 1 2 Sicurezza del macchinario concetti fondamentali principi generali di pr...

Страница 32: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...

Отзывы: