www.larius.com
15
GIOTTO FOR SANITATION
REV. 01 - 04/2020 - Cod. 150113
Apparecchi per verniciatura
ATTENZIONE
UTILIZZARE GRUPPI ELETTROGENI
CON ALTERNATORE ASINCRONO
http: www.larius.com
Paint spraying units
WARNING
USE POWER UNITS WITH
ASYNCHRONOUS ALTERNATOR
e-mail [email protected]
®
®
L
M
L1
Fig. 1L
Fig. 2L
REPLACING HYDRAULIC OIL
After operating for 100 hours, replace the oil in the pump;
• Discharge the waste oil through the
hydraulic filter
fitted
at the bottom of the pump casing.
• Clean and, if necessary, replace the worn seals.
• Replace the filter in its seat by screwing it tightly.
• Fill the pump with the recommended oil until it reaches
the maximum level.
• Then, substitute the oil every 250 hours.
CLEANING THE MOTOR COOLING FAN GUARD
Clean the motor cooling fan protection guard periodically to
ensure the best cooling.
ROUTINE MAINTENANCE
TOP UP HYDRAULIC OIL
With each start up, check the hydraulic oil level by looking through
the gauge on the side of the hydraulic body. If necessary, use
“AGIP OSO 46 type hydraulic oil”
to top up the level.
RELEASE THE SUCTION VALVE
If the pump malfunctions, release the suction valve fitted on the
head of the pump in the following way:
• Remove the suction hose fitting and release the valve
by inserting a rigid rod (
L1
) with a diameter of no more
than 15 mm.
CLEANING THE COMPRESSION VALVE
When the compression valve must be removed, clean it with
specific solvents depending on the type of sanitizing liquid used
and refit all parts by inverting the removal order.
WARNING PLATE