26 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 27
APPENDIX A
SECTION 4 |
Parameter Setup
WAKE UP POINT:
If the unit is in "Power Save Mode" and the value of the AC power of the load rises to
"WAKE UP POINT", the unit will quit "Power Save Mode" and will start operating in full volt-
age "Inverting Mode".
SELECT GROUP
CHARGE CURVE
SELECT GROUP
OTHER FUNCTION
WAKE UP POINT
7W / 10W
POWER SAVING
1 = Enable
Up Key x 4
ò
Enter Key
ò
Up Key x 2
ò
REMOTE SWITCH:
This selection is used when ON/OFF control of EVO Inverter Charger is desired through exter-
nal 12 VDC signal fed to Remote ON/OFF terminals on the Front Panel of EVO Inverter Char-
ger (15, Fig 2.1 in EVO Inverter Charger Owner's Manual) On/Off Logic Diagram is shown in
Fig 4.8 below:
0 = Button Type:
12VDC signal is fed through Push Button Type of Switch.
•
Momentary contact of Push Button > 2 sec will switch EVO Inverter Charger ON
1 = Switch Type:
1
st
12VDC input
> 2 sec will switch ON
EVO Inverter Charger
After power ON,
12VDC input < 5 sec
will have no effect
After power ON,
12VDC input > 5 sec
will switch OFF
EVO Inverter Charger
12VDC input is
available - Power On
No 12VDC input
for 2 sec - Off
Fig 4.8. On/Off Logic Diagram for Remote Switch Options
!
CAUTION!
On/Off Logic shown in Fig 4.8 also controls the operation of the On/Off Button on the front
panel of EVO Inverter Charger (11, Fig 2.1 in EVO Inverter Charger Owner's Manual). The
Default Setting is "Button Type".
If the On/Off control is changed to external "Remote Switch", it will not be possible to switch
On/Off the EVO Inverter Charger from the front panel On/Off Push Button because it will
work with Switch Type Logic at Fig 4.8: it will be ON only as long as the Push Button is kept
pressed and will switch off when released.
SELECT GROUP
CHARGE CURVE
SELECT GROUP
OTHER FUNCTION
REMOTE SWITCH
0 = Button
POWER SAVING
1 = Enable
Up Key x 4
ò
Enter Key
ò
Up Key x 3
ò
RELAY FUNCTION:
This is to select the function of Status Relay.
0 = Charger/Other. When the EVO Inverter Charger is in Charging Mode, the Status Relay
turns OFF; in Other Mode (other than Charging Mode, the Relay is ON.
Содержание Evolution EVO-2212
Страница 89: ...SAMLEX AMERICA INC 89 Notes ...
Страница 90: ...90 SAMLEX AMERICA INC Notes ...
Страница 91: ...SAMLEX AMERICA INC 91 Notes ...
Страница 133: ...SAMLEX AMERICA INC 41 APPENDIX A Notes ...
Страница 134: ...42 SAMLEX AMERICA INC APPENDIX A Notes ...
Страница 135: ...SAMLEX AMERICA INC 43 APPENDIX A Notes ...