background image

 

      Powersine Combi

 

27 

 

9. DECLARATION OF CONFORMITY 

 

 
IMPORTER        :  Samlex Europe B.V. 
ADDRESS        :  Aris van Broekweg 15 

1507 BA ZAANDAM 
The Netherlands 
 

Declares that the following products : 
   
PRODUCT TYPE    :  Professional inverter / charger combination 
MODELS         :  PSC1600-12-60, PSC1800-24-35, PSC2000-12-80, PSC2500-24-50,  
                PSC3000-12-120, PSC3500-24-70 
 
Conforms to the requirements of the following Directives of the European Union : 
 

EMC Directive 2004/108/EC 

 
The above product is in conformity with the following harmonized standards : 
 
Low Voltage Directive 2006/95/EC 
EN61000-6-3 : 2001 EMC - Generic Emissions Standard 
EN61000-6-2 : 2005 EMC - Generic Immunity Standard 
EN60335-1 : 1999 Generic safety standard 
EN60335-2-29 : 2004 Safety requirements for battery chargers 
 
 
 
Zaandam, February 2014 
 
 
 
 
 
M. van Veen 
 
 
 

 

Содержание PSC1600-12-60

Страница 1: ...800 24 35 PSC2500 24 50 PSC3500 24 70 Model No SINEWAVE INVERTER CHARGER Manual Gebruiksaanwijzing Benutzerhandbuch Manuel Utilisateur Manual Para Utilizador Please read this manual before operating y...

Страница 2: ...SSES DAMAGES COSTS OR EXPENSES WHETHER SPECIAL DIRECT INDIRECT CONSEQUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE...

Страница 3: ...12 4 1 Operating the Powersine Combi 12 4 2 Powersine Combi LED indicators and error modes 12 4 2 1 Error indications 14 4 3 Programmable Alarm relay 14 4 4 Trigger input 15 4 5 Load requirements in i...

Страница 4: ...of this owner s manual is to provide explanations and procedures for operating and configuring the Powersine Combi For installing the Powersine Combi a separate installation guide is included The inst...

Страница 5: ...ting the inverter The connected loads are now supplied again by the grid generator without any interruption Additionally the Powersine Combi offers features like AC Input Power Boost which temporarily...

Страница 6: ...gured in SAMLEX Dashboard When DIP switch 1 is set to OFF Local again DIP switch 2 up to 7 or 9 are overriding the corresponding parameter settings previously made in SAMLEX Dashboard The parameters t...

Страница 7: ...Parameter AC input voltage range transfer switch Value 180V 270V Description Input voltage range which is accepted by the Powersine Combi for feeding through to the connected load Two AC undervoltage...

Страница 8: ...nd Dashboard Parameter AC input fail sensitivity Value Normal Description This parameter can be set to Very Low Low Normal High and Very High The value of this Parameter decides how fast the Powersine...

Страница 9: ...w During step 3 of the installation guide you can alter the factory settings of the DIP switches to change the functionality of the Powersine Combi on a few points For additional information about the...

Страница 10: ...age 13 3V 26 6V programmable Factory setting OFF AC Input Power Boost ON AC Input Power Boost on OFF AC Input Power Boost o Factory setting ON Models PSC1600 1800 Bypass remote switch Bypasses the rem...

Страница 11: ...e serious damage to your batteries and or connected battery loads Always consult your battery s documentation for the correct charge voltage settings 2 When charging and discharging lithium batteries...

Страница 12: ...lease the AC transfer switch and activate the inverter again All this happens so fast that the connected load will not be disturbed When switched to Off the Powersine Combi is completely shut down and...

Страница 13: ...as well as the status of each different mode see explanation below charger on LED Off not charging On green charging On blinking red error see chapter 4 2 1 On red charger disabled inverter on LED Off...

Страница 14: ...s in a row Device error an error has occurred inside the Powersine Combi Please return for service Five flashes in a row Charge program error only for charger on indicator LED Charge program selection...

Страница 15: ...ce the Powersine Combi to switch to inverter mode All this can be configured in SAMLEX Dashboard The PSC1600 1800 models are equipped with one trigger input while the PSC2000 3500 models are equipped...

Страница 16: ...80 full indicator will be lit This stage will return the final 20 of charge to the battery The output voltage is kept at a constant level and the charge current decreases as a function of the battery...

Страница 17: ...ements must be read carefully When the battery temperature sensor is installed the charger automatically compensates the charge voltages against battery temperature except when set to Lithium This mea...

Страница 18: ...button on the bottom side of the unit see images below for 3 seconds until all charge status indicators start flashing Models PSC1600 1800 Models PSC2000 3500 The Powersine Combi will allow a maximum...

Страница 19: ...r mode is not working AC transfer switch does not activate either The AC input voltage or frequency are out of range or too unstable Make sure that the AC input voltage is between 185V 270V and the fr...

Страница 20: ...eck the DC system for an external source that pushes the battery voltage too high Too high ripple voltage on DC input manual restart needed Check battery wire connections Decrease battery cable length...

Страница 21: ...cy borders Make sure that the AC input voltage falls within 185V 270V and 45Hz 65Hz All mode indicator LEDs inverter on charger on and AC in are blinking red twice per second manual restart needed Max...

Страница 22: ...rogram contains go to error condition for example when a charge stage takes too much time If none of the above remedies will help solving the problem you encounter it s best to contact your local SAML...

Страница 23: ...bled Yes Protections high low battery voltage high temperature overload short circuit high ripple voltage and low AC input voltage DC connections Two wires length 1 5 meters 35mm2 AC connections Screw...

Страница 24: ...led Yes Protections high low battery voltage high temperature overload short circuit high ripple voltage and low AC input voltage DC connections M10 bolt terminals AC connections Screw terminals Enclo...

Страница 25: ...bled Yes Protections high low battery voltage high temperature overload short circuit high ripple voltage and low AC input voltage DC connections M10 bolt terminals AC connections Screw terminals Encl...

Страница 26: ...of the product and product malfunctioning Since SAMLEX cannot control the use and installation according to local regulations of their products the customer is always responsible for the actual use of...

Страница 27: ...2500 24 50 PSC3000 12 120 PSC3500 24 70 Conforms to the requirements of the following Directives of the European Union EMC Directive 2004 108 EC The above product is in conformity with the following h...

Страница 28: ...www samlex com www samlex solar com...