Powersine Combi
10
Factory se
tti
ng = OFF
ASB mode
ON : ASB mode on
OFF : ASB mode o
ff
Factory se
tti
ng 5 = OFF
Factory se
tti
ng 6 = ON
Ba
tt
ery type / Charge program
1)
5 = OFF : Ba
tt
ery type = Flooded
6 = OFF Absorp
ti
on voltage = 14.4V or 28.8V
Float voltage = 13.5V or 27.0V
5 = ON : Ba
tt
ery type = GEL
6 = OFF Absorp
ti
on voltage = 14.2V or 28.4V
Float voltage = 13.5V or 27.0V
5 = OFF : Ba
tt
ery type = AGM
6 = ON Absorp
ti
on voltage = 14.3V or 28.6V
Float voltage = 13.3V or 26.6V
5 = ON : Ba
tt
ery type = Lithium
2)
/ Custom
6 = ON
Absorption voltage = 14.4V / 28.8V (programmable)
Float voltage =
13.3V / 26.6V (programmable)
Factory se
tti
ng = OFF
AC Input Power Boost
ON : AC Input Power Boost on
OFF : AC Input Power Boost o
ff
Factory se
tti
ng = ON
Models : PSC1600-1800
Bypass remote switch
(
Bypasses the remote switch
connec
ti
on when no remote switch is connected)
ON : Remote switch connec
ti
on terminals are bypassed
OFF : remote switch connec
ti
on terminals are open. A
remote switch must be connected and switched ON
in order to ac
tiva
te the Powersine Combi. The local
on/o
ff
switch on the frontpanel always overrides the
remote switch. So in order to use the remote switch,
the local on/o
ff
switch must be in the 'on' or
'charger only' posi
ti
on.
Models : PSC2000-3500
Ground switch/relay
ON : Ground switch is enabled
OFF : Ground switch is disabled