3. CONFIGURING THE POWERSINE COMBI
3.1 General
The Powersine Combi can be configured in two ways. Using the DIP switches located in the
connection bay, a small selection of basic settings can be made. In most cases this will be
sufficient to quickly setup the unit for typical applications. Another option is to setup the
Powersine Combi using the SAMLEX Dashboard for Windows software. This software is
included in the optional SAMLEXLink to USB Communication Kit (art.# 64660), which also
contains an isolated interface box required to connect the Powersine Combi to a PC. Using
SAMLEX Dashboard, all available parameters can be edited, and it is also possible to edit or
create your own battery charge programs.
!
CAUTION
When configuring the Powersine Combi by SAMLEX Dashboard, make sure that DIP switch 1
is set to ON (External). When set to ON, all remaining DIP switch settings (2 up to 7 or 9) are
ignored and the Powersine Combi will always load the parameter settings as configured in
SAMLEX Dashboard.
When DIP switch 1 is set to OFF (Local) again, DIP switch 2 up to 7 or 9
are overriding the
corresponding parameter settings previously made in SAMLEX Dashboard. The parameters
that cannot be configured by DIP switches, shall return to the factory default settings.
This manual will only describe the DIP switch settings and all relevant factory default
parameters. Configuration by SAMLEX Dashboard will be explained in the SAMLEX
Dashboard manual that comes with the SAMLEXLink to USB Communication Kit.
3.2 Factory default parameter settings
The table below shows an overview of the most relevant factory parameter settings, as
stored in the Powersine Combi. These settings are based on an average application. SAMLEX
cannot guarantee that these are correct for your specific application. Please check all
parameters carefully, especially the battery charging voltages.
Parameter
Inverter frequency
Value
50Hz
Description
Output frequency in inverter mode. Can be set to 50Hz or 60Hz
Configurable by
DIP switch (DIP 2) and Dashboard
Parameter
Inverter voltage
Value
230V
Description
Output voltage in inverter mode. Can be set from 200V to 240V
Configurable by
Dashboard