www.reikalevy.fi
33
Sensor distance:
Distance from photoelectric sensors to cutting unit. Only affects the length of the first and last cut
from the wood. See more at the section “cutting length adjustment”.
Diam. Meas. Delay:
Delay between presser control valve activation and wood thickness measurement.
Pusher F delay:
Defines how long the pusher is moved forward in order to push the wood to splitting spout.
Pusher B delay:
Defines how long pusher is waited to move back before continuing operation.
Sawing time:
Defines the time in which the saw must reach lower inductive sensor. If the time is exceeded the
sawing procedure is repeated 5 times. If the inductive sensor is still not reached machine operation is
stopped.
Saw up time:
Defines the time in which rising saw must reach upper inductive sensor.
Splitting F time:
Defines the time in which forward moving splitting piston must reach the front limit.
Splitting B time:
Defines the time in which backward moving splitting piston must reach the back limit.