www.reikalevy.fi
29
8.3
Cutting unit
•
Sensing distance of the sensors is 8 mm.
•
Loosen the locknuts marked with yellow arrows (17 mm wrench) and move the
sensors so that there’s about 2 mm between the sensors and the screw marked with
red arrow.
•
If the sensors need to be adjusted vertically, loosen the sensor holders (5 mm hex
key) and move the holders.