www.reikalevy.fi
30
8.4
Log lifter
Log lifter sensor is attached to the feed conveyor.
•
Sensing distance of the sensor is 8 mm.
•
Loosen the locknut marked with yellow arrow (17 mm wrench) and move the
sensor so that there’s about 2 mm between the sensor and the log lifter.
•
Adjust sensor vertically so that the log lifter is flush with the feed conveyor.
Log lifter flush with the feed conveyor.