Index revision : A
11
7159
1.6. Important recommendations
1.6.1. Ventilation
Do not start the powder application with the Inogun M spray gun until the spray booth ventila-
tion system is switched on. If the ventilation is switched off, toxic substances or dust may remain
in the spray booth and cause a risk of fire, poisoning or irritation.
1.6.2. O-ring seals
Use the seals recommended in this manual.
1.6.3. Ambient temperature
The equipment is designed to normally operate at an ambient temperature comprised
between 0°C and + 40°C.
The storage temperature must never 60°C.
1.6.4. Sound level
The sound pressure level generated by Inocart VT is equal to 80.2 dBA and 78.1 dBA for the
Inocart H under the specified operating conditions.
Conditions of measurement:
The equipment was put into operation at maximum characteristics, the measurements were
carried out at different positions at 1 m from the cart without powder in the Powder laboratory
at the
SAMES KREMLIN
site in Meylan, France.
Method of measurement:
The accoustic pressure level, continuous, equivalent, weighted (80.2 dBA or 78.1 according to
the version of the cart) is given in LEQ value, measured for observation periods of at least 30
seconds.