SAMES KREMLIN
Page 14
Manual : 573.190.112
SUCTION KIT ( Refer to Doc. 573.396.050) (14)
BELLOWS (60)
Disassembly :
Disassemble the whole (HB & 14) from the pump unscrewing
the nuts (10) from the tie-rods (4) and removing the axis (7) and
the pin (8) at the flange (11) level.
Remove the cylinder and the exhaust valve from the
CATALYST fluid section.
On the suction kit (14) :
Take off the nuts (71), remove the flange (65).
Pull the suction bearing (64) upwards. The bellows (61), the
skirt (62), the coupling rod (63) and the CATA piston rod (41)
are drawn in by the suction bearing.
Take off the ring (67) located on the flange (65).
Take off the cylinder (69).
Disassemble the CATA piston rod (41) from the coupling rod
(63).
Push the CATA fluid section cartridge to take off the flange (70).
Assembly :
Lubricate the seals and the ring (66 & 67) before installing
them.
Install new seals (66) into the fluid flange (70) and into the
suction bearing (64).
Install the ring (67) into the flange (65). Make it strain to insert it
in its housing.
Install the cylinder (69) into the flange (70) until to stop
(overcome the stiffness of the seal (66) without damaging it).
Slide the coupling rod (63) into the new bellows assembly
(bellows, 61 and skirt, 62).
Associate the coupling rod (63) and the CATA piston rod (41)
after the application of glue (low strength - Aneorobic adhesive -
Loctite 222). Screw the 2 rods together (insert a metal rod on
the holes located at each end and tighten).
Locate the whole (bellows and rods) into the suction bearing
(64).
Place the whole on the tie-rods (68) as well as the flange (65).
Install the nuts (71).
Caution : Tighten them manually to get a play
between the parts.
Mount the coupling rod (63) on the upper part of the pump by
means of the axis (2) and the pin (3) - consult drawing of the
previous page.
If necessary, orientate the coupling rod (63) with care
to prevent from damaging the bellows (61).
It is possible when the nuts (71) are not too tightened.
When the parts are installed, tighten the nuts (71) with a wrench
# 10.
Install a new cartridge (43) before mounting the CATA fluid
section.
63
62
64
66
69
66
68
70
67
71
65
61