22
•
SPS-300 Series Program Information
SPS-300 SmartECR Supplement v1.11
MPP TIP Function Key
Beginning at STE v01.109 a new MPP TIP function key
(key code 418)
is provided for entering Tip’s in
register mode. If your application is set for “Fine Dining” you must place the MPP TIP function on the
keyboard. The MPP TIP key can be set to require manager approval for tip entry if desired.
The MPP TIP key allows you to enter gratuities without having to turn the mode lock to the Z position.
Refer to “TIP (Gratuity) Entry” on page 37 for the TIP entry operation.
Note: MPP TIP operation is performed outside a transaction.
1.
From the
PGM
control lock position menu, press
5
for
FUNCTION KEY
. The
FUNCTION
KEY PROGRAM
screen displays:
2.
Press the Datatran Tip function key to view the associated function key options:
MPP TIP P ROGRAM MING
DESC : MP P TIP
UNDER MGR CONTR OL N
SEND TO E FT
Y
Required
Setting
3.
Select
Y
(YES) or
N
(NO) for manager control.
4.
Set
Y
(YES) for the “SEND TO EFT option.
5.
Press the
CASH
key to finalize and then press
CLEAR
return to the main
PROGRAM MODE
screen.
Note: If updating from the mBox to the SmartECR, do not load back the function key program
area; The Function key file has changed. If you do load back function keys, you will need to go back
and reprogram the descriptor for the MPP TIP function.