SPS-300 SmartECR Supplement v1.11
SPS-300 Series Program Information
•
13
SPS-320/SPS-340 Memory All Clear
1.
Turn the power switch located on the right side of the register to the
OFF
position.
2.
Turn the control lock to the
S
position.
SPS-320 and SPS-340
Press and hold the
CHECK
key position
during power-up in
S
d
3.
Press and hold the key position where the
CHECK
key is located on the default keyboard layout:
1
3
2
4
SPS-320
SPS-340
4.
Continue to hold the
CHECK
key while turning the power switch to the
ON
position. The
message “RAM ALL CLEAR" displays.
5.
Press the
upper left
key of the keyboard, then the
lower left
key, then the
upper right
key, and
finally press the
lower right
key:
1
3
2
4
SPS-320
SPS-340
6.
After a short delay, the printer will display the message: "Please Wait…". Memory is cleared, the
default program is installed and the RAM CLEAR receipt is printed. The display now reads:
“PRINTER 2STATION; Y=CASH N=CLEAR”.
7.
If you have an SPS-320 (one printer station), press
CLEAR
.
If you have an SPS-340 (two printer stations), press
CASH
.
8.
The display now reads:
AUTO CUT : ‘CASH’ Key
NO CUT : ‘CLEAR’ Key
9.
Press
CLEAR
.
10.
The display now reads: “SERVICE MODE; CLOSED”. The RAM Clear procedure is complete.
The ECR is now ready to program or to load a previously saved program file.