8-4
Module 2 – Wireless Accessories
SC904ZB Inline Shutoff Valve
Section 8
Installation Instructions
Step 4.
Using the SALUS Smart
Home application, close the valve
to be sure it operates correctly
and no interferences exist .
Step 5.
Open the valve using
the app and watch for proper
operation .
In case of a weak wireless
signal, a wireless repeater
may be required .
To operate the valve locally, without the SALUS Smart Home app, press and release the Multi-Function Button .
The chart above describes the resulting actions based on the current state of the valve .
This device should be installed by a qualified plumber. Installations and repairs are to be
performed in strict accordance with the requirements of state and local regulating agencies
and codes dealing with plumbing installations.
Step 1.
Identify the location
for the Inline Shutoff Valve to
control the desired water supply .
Make sure that the valve is
accessible and there is adequate
clearance for operation of the
Manual Override Lever .
Step 2.
Install the valve
using appropriate ¾” NPT
fittings, adapters and thread
sealant . Check for leaks before
proceeding to power the valve .
Step 3.
Connect the power
adaptor to the jack provided
under the waterproof cap
inserting the cable into the cable
clip
. This provides strain
relief to avoid accidental power
disconnection .
Local Opening/Closing the Inline Shutoff Valve
Valve State
Multi-Function Button Action
Fully Closed
Start opening valve
Fully Open
Start closing valve
In Motion
Stop valve at its current position
Partially Open Moves valve toward fully open/closed
(opposite of last direction)
Multi-Function