3-5
Module 2 – Wireless Accessories
SS882ZB Door/Window Sensor
Section 3
Step 1.
Remove the
SS882ZB Sensor from
the Mounting Plate,
exposing the battery
attached to the Sensor .
Step 4.
Open the Magnet
Case and position the bottom
housing to the surface using
the provided screws or double-
sided tape . Once it is secure,
snap the top housing with
the magnet onto the bottom
housing .
Step 5.
With the door or window
closed, make sure the dashboard
icon shows a closed window .
Step 6.
Open the window and
make sure the window icon is
open and, after 60 seconds, the
Issue indicator will register the
issue .
Battery Replacement
If the battery is low, the sensor icon on the SALUS Smart Home
dashboard will turn red and the Issue indicator will register a
message . Use only Panasonic CR3032 or EVE Energy CR3032 to
meet UL certification requirements .
Battery Disposal
Lithium batteries are considered hazardous waste in most
municipalities . Dispose of the used lithium batteries in accordance
with all applicable local regulations .
Step 4.
Snap the
Sensor back onto
the Mounting Plate,
making sure the
rounde corners
match .
Step 2.
Lift the battery
to remove it from the
battery socket .
Step 3.
Insert the new
battery into the socket .
Make sure the positive
terminal faces up after
inserting .