background image

7

4.

Press the 

Enter

 key to accept the keyed in number. (If you make an 

error in keying in the number, press the 

Clear

 key to clear the count in 

the COUNT window and re-key the correct number.)…

The scale calculates the weight of each piece (the piece weight) and 
displays the count in the COUNT window.

5.

Place the items to be counted on the scale…

The total weight, piece weight and count of the items will be shown in 
the three display windows respectively.

6.

Remove the items from the scale and repeat steps 5 and 6 to count 
items of the same piece weight.

7.

Repeat steps 1-6 to count items of a different piece weight.

Note: Piece weight is displayed in grams/decimal grams or LB/decimal 
pounds. 

Note: The original piece weight will be held in memory until a new piece 
weight has been determined. Turn the scale off, then on to return to normal 
weighing mode.

Counting by Entering a Known Piece Weight

You can enter a known piece weight and begin counting without sampling.

This can also be used with the tare function active. After you have set the piece 
weight, place the item to be tared on the scale, press the 

Tare

 key and 

continue with counting as described below.

Follow these steps:

1.

Turn the scale on and zero the display, if necessary, using the 

Zero

 key. 

Be sure the scale is displaying weight in your preferred unit of measure. 
Change it using the 

Units

 key, if necessary.

2.

Press the 

Pcwt

 key…

PC.t

 is displayed in the COUNT window and zeroes are displayed in 

the WEIGHT and PIECE WEIGHT windows.

3.

There is a decimal point already in the PIECE WEIGHT window. Key in 
the known piece weight, in decimal pound or grams, using the numeric 
keypad so that the piece weight in the PIECE WEIGHT window is 
correct, then press the 

Enter

 key to accept this piece weight. (If you 

make an error in keying in the number, press the 

Clear

 key to clear the 

number and re-key the correct number.)

The counting mode activates using the entered piece weight.

Содержание B 120

Страница 1: ...p n AWT35 500140 Issue AB July 2007 MODEL B 120 Counting Scale User Manual...

Страница 2: ...is intended for use in dry conditions For your protection all mains 110V or 240V equipment used out of doors or in wet or damp conditions should have adequate environmental protection We recommend a c...

Страница 3: ...20 hours Place the scale on a stable level surface Level the scale using the adjustable feet and the bubble level at the lower left of the front panel Tighten the locking ring on each foot once the sc...

Страница 4: ...rminal and the black wire to the black battery terminal Place battery in the compartment with the padding placed as shown and replace the battery cover and tighten the screw Note To improve battery li...

Страница 5: ...This lights when a tare is in effect Weight displayed is net weight kg This lights when the unit of measure in the WEIGHT display is kilograms lb This lights when the unit of measure in the WEIGHT dis...

Страница 6: ...100 of capacity an empty container or weight not required in the calculation of an average piece weight Use of tare will reduce the scale s maximum weight capacity by the tare value stored Accu Used t...

Страница 7: ...objects in a container follow these steps 1 Turn the scale on and zero the display if necessary by pressing the Zero key Be sure the scale is displaying weight in your preferred unit of measure Chang...

Страница 8: ...lays the number entered If the piece weight window shows SPL PCS press the CLEAR key and increase your sample weight Counting by Sampling Follow these steps to count items using the sampling method Fo...

Страница 9: ...ntering a Known Piece Weight You can enter a known piece weight and begin counting without sampling This can also be used with the tare function active After you have set the piece weight place the it...

Страница 10: ...e scale on and zero the display if necessary using the Zero key Be sure the scale is displaying weight in your preferred unit of measure Change it using the Units key if necessary 2 Use sampling or en...

Страница 11: ...nt is displayed press the Accu key to accumulate the count to memory The count is added into memory and temporarily Add is displayed in the WEIGHT window the number of accumulations is displayed in th...

Страница 12: ...he COUNT window will alternately flash H 1234 and L 5678 Note Remove the counted items from the scale and let the scale return to stable condition before you can count more items and perform a success...

Страница 13: ...ograms When the unit you want is displayed press the Enter key to accept it The scale beeps and unLoAd is displayed in the PIECE WEIGHT window A number representing raw A to D counts is displayed in t...

Страница 14: ...WEIGHT window the word codE is displayed in the PIECE WEIGHT window and the A to D counts code is displayed in the COUNT window Vol stands for voltage and X X is the current voltage of the battery If...

Страница 15: ...ly 2 Key in the number of minutes of scale inactivity that will trigger the auto off function and press the Enter key to accept this value The scale returns to normal mode 8 0 Setting LED Brightness Y...

Страница 16: ...Err There is an error in calibration maybe the loaded weight is too small or the input weight is not correct Ad Input signal of ADC is over max range Ad _ _ _ _ Input signal of ADC is below min range...

Страница 17: ...s below 5 5V the scale beeper will sound and work for approximately two minutes before powering off When the scale is powered by the AC adapter the AC annunciator will turn on When the battery is char...

Страница 18: ...16...

Страница 19: ...0 444 6132 Fax 44 0 870 010 2241 Email sales salterbrecknell co uk Web Site www averyweigh tronix com USA Salter Brecknell Weighing Products USA 1000 Armstrong Drive Fairmont MN 56031 Toll free 800 63...

Отзывы: