General Counting Information

If there is no piece weight, the scale will not go into count mode.

Once a piece weight is established, it remains active until another piece weight 
is automatically calculated by a sampling process.

After counting items, remove them and the display should return to zero. If not, 
press the 

ZERO

 key.

A counting scale needs a minimum amount of weight to calculate counts with 
accuracy. Salter Brecknell recommends the sample weight be a minimum of 
0.1% of scale capacity. The sample weight is the total weight of your sample 
items. The table below shows the minimum sample weights recommended to 
guarantee the most accurate counts.

 After entering the number of samples and pressing the 

Enter

 key, the count 

window displays the number entered. If the piece weight window shows 

SPL 

PCS

, press the 

CLEAR

 key, and increase your sample weight.

Counting by Sampling

Follow these steps to count items using the sampling method. 

For count accuracy all items should be uniform in weight. Errors in count will 
occur if parts vary in weight.

1.

Turn the scale on and zero the display, if necessary, using the 

Zero

 key. 

Be sure the scale is displaying weight in your preferred unit of measure. 
Change it using the 

Units

 key, if necessary.

2.

Place a known number of objects on the scale. This is the sample 
weight the scale will use to calculate a piece weight…

Weight of the items is displayed in the WEIGHT window.

3.

Key in the number of objects you placed on the scale…

SPL.PCS

 is displayed in the PIECE WEIGHT window and the number 

you keyed in is displayed in the COUNT window.

Minimum Sample Weight

Scale Capacity

LB

Grams

6 kg/12 lb

0.02

6

15 kg / 30 lb

0.05

15

30 kg / 60 lb

0.1

30

Содержание B 120

Страница 1: ...p n AWT35 500140 Issue AB July 2007 MODEL B 120 Counting Scale User Manual...

Страница 2: ...is intended for use in dry conditions For your protection all mains 110V or 240V equipment used out of doors or in wet or damp conditions should have adequate environmental protection We recommend a c...

Страница 3: ...20 hours Place the scale on a stable level surface Level the scale using the adjustable feet and the bubble level at the lower left of the front panel Tighten the locking ring on each foot once the sc...

Страница 4: ...rminal and the black wire to the black battery terminal Place battery in the compartment with the padding placed as shown and replace the battery cover and tighten the screw Note To improve battery li...

Страница 5: ...This lights when a tare is in effect Weight displayed is net weight kg This lights when the unit of measure in the WEIGHT display is kilograms lb This lights when the unit of measure in the WEIGHT dis...

Страница 6: ...100 of capacity an empty container or weight not required in the calculation of an average piece weight Use of tare will reduce the scale s maximum weight capacity by the tare value stored Accu Used t...

Страница 7: ...objects in a container follow these steps 1 Turn the scale on and zero the display if necessary by pressing the Zero key Be sure the scale is displaying weight in your preferred unit of measure Chang...

Страница 8: ...lays the number entered If the piece weight window shows SPL PCS press the CLEAR key and increase your sample weight Counting by Sampling Follow these steps to count items using the sampling method Fo...

Страница 9: ...ntering a Known Piece Weight You can enter a known piece weight and begin counting without sampling This can also be used with the tare function active After you have set the piece weight place the it...

Страница 10: ...e scale on and zero the display if necessary using the Zero key Be sure the scale is displaying weight in your preferred unit of measure Change it using the Units key if necessary 2 Use sampling or en...

Страница 11: ...nt is displayed press the Accu key to accumulate the count to memory The count is added into memory and temporarily Add is displayed in the WEIGHT window the number of accumulations is displayed in th...

Страница 12: ...he COUNT window will alternately flash H 1234 and L 5678 Note Remove the counted items from the scale and let the scale return to stable condition before you can count more items and perform a success...

Страница 13: ...ograms When the unit you want is displayed press the Enter key to accept it The scale beeps and unLoAd is displayed in the PIECE WEIGHT window A number representing raw A to D counts is displayed in t...

Страница 14: ...WEIGHT window the word codE is displayed in the PIECE WEIGHT window and the A to D counts code is displayed in the COUNT window Vol stands for voltage and X X is the current voltage of the battery If...

Страница 15: ...ly 2 Key in the number of minutes of scale inactivity that will trigger the auto off function and press the Enter key to accept this value The scale returns to normal mode 8 0 Setting LED Brightness Y...

Страница 16: ...Err There is an error in calibration maybe the loaded weight is too small or the input weight is not correct Ad Input signal of ADC is over max range Ad _ _ _ _ Input signal of ADC is below min range...

Страница 17: ...s below 5 5V the scale beeper will sound and work for approximately two minutes before powering off When the scale is powered by the AC adapter the AC annunciator will turn on When the battery is char...

Страница 18: ...16...

Страница 19: ...0 444 6132 Fax 44 0 870 010 2241 Email sales salterbrecknell co uk Web Site www averyweigh tronix com USA Salter Brecknell Weighing Products USA 1000 Armstrong Drive Fairmont MN 56031 Toll free 800 63...

Отзывы: