background image

15

10.0

Specifications

Power supply

a).

12VDC 500mA output, with positive center, AC adapter 

b).

 6V4A rechargeable lead-acid battery

Average working current:

120mA  when LED’s brightness is set to 1

200mA  when LED’s brightness is set to 2(default)

300mA when LED’s brightness is set to 3

Note:  The LED life is shortened when set to level 3. 

Note: The rechargeable battery is fully charged after 12 hours and the scale can work 
continuously for approximately 20 hours. Once voltage drops below 5.7V, the Low Batt 
annunciator lights. Once the voltage drops below 5.5V, the scale beeper will sound and 
work for approximately two minutes before powering off. 

When the scale is powered by the AC adapter, the 

AC

 annunciator will turn on. 

When the battery is charging, the 

CHG

 annunciator lamp will be on.

Model

B120

Capacity

6kg/12lb

15kg/30lb

30kg/60lb

Display 

Resolution

6kg x 0.001kg
12lb x 0.002lb

15kg x 0.002kg

30lb x 0.005lb

30kg x 

0.005kg

60lb x 0.010lb

Max. Display 

Weight

6.009kg/
13.248lb

15.018kg/33.110lb

30.045kg/

66.240lb

TARE Range

0-100% of full scale capacity

ZERO Range

Power on:calibration zero point±10% of full scale 

capacity; 

Zero key:power on zero point±5% of full scale capacity

Count Display 

Range

0-16777216

Conversion 

factors

used for Kg and 

Lb

1Lb=0.45359237kg   or  1Kg=2.20462262Lb

Содержание B 120

Страница 1: ...p n AWT35 500140 Issue AB July 2007 MODEL B 120 Counting Scale User Manual...

Страница 2: ...is intended for use in dry conditions For your protection all mains 110V or 240V equipment used out of doors or in wet or damp conditions should have adequate environmental protection We recommend a c...

Страница 3: ...20 hours Place the scale on a stable level surface Level the scale using the adjustable feet and the bubble level at the lower left of the front panel Tighten the locking ring on each foot once the sc...

Страница 4: ...rminal and the black wire to the black battery terminal Place battery in the compartment with the padding placed as shown and replace the battery cover and tighten the screw Note To improve battery li...

Страница 5: ...This lights when a tare is in effect Weight displayed is net weight kg This lights when the unit of measure in the WEIGHT display is kilograms lb This lights when the unit of measure in the WEIGHT dis...

Страница 6: ...100 of capacity an empty container or weight not required in the calculation of an average piece weight Use of tare will reduce the scale s maximum weight capacity by the tare value stored Accu Used t...

Страница 7: ...objects in a container follow these steps 1 Turn the scale on and zero the display if necessary by pressing the Zero key Be sure the scale is displaying weight in your preferred unit of measure Chang...

Страница 8: ...lays the number entered If the piece weight window shows SPL PCS press the CLEAR key and increase your sample weight Counting by Sampling Follow these steps to count items using the sampling method Fo...

Страница 9: ...ntering a Known Piece Weight You can enter a known piece weight and begin counting without sampling This can also be used with the tare function active After you have set the piece weight place the it...

Страница 10: ...e scale on and zero the display if necessary using the Zero key Be sure the scale is displaying weight in your preferred unit of measure Change it using the Units key if necessary 2 Use sampling or en...

Страница 11: ...nt is displayed press the Accu key to accumulate the count to memory The count is added into memory and temporarily Add is displayed in the WEIGHT window the number of accumulations is displayed in th...

Страница 12: ...he COUNT window will alternately flash H 1234 and L 5678 Note Remove the counted items from the scale and let the scale return to stable condition before you can count more items and perform a success...

Страница 13: ...ograms When the unit you want is displayed press the Enter key to accept it The scale beeps and unLoAd is displayed in the PIECE WEIGHT window A number representing raw A to D counts is displayed in t...

Страница 14: ...WEIGHT window the word codE is displayed in the PIECE WEIGHT window and the A to D counts code is displayed in the COUNT window Vol stands for voltage and X X is the current voltage of the battery If...

Страница 15: ...ly 2 Key in the number of minutes of scale inactivity that will trigger the auto off function and press the Enter key to accept this value The scale returns to normal mode 8 0 Setting LED Brightness Y...

Страница 16: ...Err There is an error in calibration maybe the loaded weight is too small or the input weight is not correct Ad Input signal of ADC is over max range Ad _ _ _ _ Input signal of ADC is below min range...

Страница 17: ...s below 5 5V the scale beeper will sound and work for approximately two minutes before powering off When the scale is powered by the AC adapter the AC annunciator will turn on When the battery is char...

Страница 18: ...16...

Страница 19: ...0 444 6132 Fax 44 0 870 010 2241 Email sales salterbrecknell co uk Web Site www averyweigh tronix com USA Salter Brecknell Weighing Products USA 1000 Armstrong Drive Fairmont MN 56031 Toll free 800 63...

Отзывы: