ENGLISH
11
Location
will
be
chosen
to
ensure
space
reservation
for
maintenance
and
inspection.
Check
that
there
is
ample
overhead
for
lifting
and
that
lifting
devices
are
available.
7.1.1
FOUNDATION
Pump
set
can
be
installed
on
various
types
of
foundations
(on
a
concrete
ground,
on
a
foundation
concrete
block,
on
a
steel
framework,
…).
It
is
the
responsibility
of
the
end
user
to
select
proper
pump
foundation
type.
Noise
level
and
vibrations
transmitted
by
the
machine
depend
on
the
quality
of
foundation.
Following
rules
are
general
instructions
that
should
be
respected
:
‐
Base
frame
or
pump
matting
plate
should
be
fastened
to
a
rigid
foundation
with
no
risk
of
distortion
while
the
pump
is
running.
‐
Make
sure
that
the
foundation
concrete
is
of
sufficient
strength
(min
quality
X0
to
DIN
1045).
Generally,
the
weight
of
foundation
is
around
3
times
the
pumpset
weight.
With
pump
set
dimensions
and
concrete
density
it
is
then
possible
to
calculate
the
dimensions
of
the
required
foundation
block.
‐
Surface
under
pumpset
should
be
flat
and
should
not
create
any
distortion
of
base
plate
after
tightening
of
foundations
bolts.
If
surface
quality
is
not
sufficient,
add
shims
between
ground
and
base
plate.
Distortion
on
base
plate
surface
should
be
limited
to
0,4mm/m
after
the
baseplate
is
definitively
fastened
to
foundations.
Coupling
alignment
is
checked
before
shipment
(pumps
and
motor
deliver
ed
on
a
common
baseplate)
If
coupling
is
not
correctly
aligned
after
installation
works
are
done
this
indicates
that
the
baseplate
has
become
twisted
and
leveling
should
be
corrected
by
re
‐
shimming.
Even
if
foundation
works
have
been
done
with
care,
it
is
necessary
to
check
coupling
alignment
after
the
baseplate
is
definitively
secured
to
the
foundation.
7.1.2
ANCHORING
Chemical
anchoring
device
should
be
preferred
to
fasten
a
baseplate
on
an
existing
foundation.
Anchor
bolts
can
be
used
if
foundation
block
is
to
be
built.
1
–
Anchor
bolt
2
–
Baseplate
3
–
Concrete
foundation
block
Folded
steel
fabricated
baseframes
will
be
grouted
to
insure
its
rigidity.
Using
of
shrink
free
grout
is
the
most
efficient.
Grouting
ensures
correct
positioning
of
the
baseframe
and
reduces
vibrations
transmission
to
civil
work.
Foundation
work
surface
preparation
and
leveling
of
baseframe
will
be
performed
in
the
state
of
the
art
and
should
be
done
before
grouting
of
the
baseplate.
Foundation
bolts
should
be
fully
tightened
only
after
the
grout
has
cured.
Installation
without
foundation
:
1
–
Intermediate
plate
2
–
Nut
3
–
Leveling
element
4
–
Foot
base
5
–
Washer
6
–
Fastening
nut
7
–
Washer
8
–
Baseplate
fastening
screw
7.1.3
POSITIONING
Pump
baseplate
(cast
iron
base
plate
or
fabricated
steel
baseframe)
should
be
installed
horizontally
to
ensure
bearings
lifetime
and
proper
flow
of
pumped
fluid.
7.1.4
COUPLING
ALIGNMENT
Pumpsets
assembled
with
a
flexible
coupling
must
be
aligned
after
the
baseframe
has
been
definitively
fastened
to
the
foundation.
Use
low
thickness
shims
(0,2
to
1
mm)
to
modify
coupling
alignment.
Adjust
the
motor
height
first.
Sometimes
it
is
necessary
to
add
shims
under
pump
feet
too.
Aligment
of
coupling
should
be
performed
with
particular
care
when
the
pumpset
is
installed
in
an
hazardous
area.
Correct
alignment
will
avoid
abnormal
increasing
of
the
pump
and
motor
ball
bearings
temperature.
Thermal
expansion
:
the
pump
and
motor
will
normally
have
to
be
aligned
at
ambient
temperature
with
an
allowance
for
thermal
expansion
at
operating
temperature.
In
pump
installation
involving
high
liquid
temperatures,
alignment
should
be
checked
again
when
operating
temperature
is
reached
(pump
and
piping).
Alignment
quality
should
be
checked
just
after
machine
shut
down.
Pump
and
driver
must
be
isolated
electrically
before
alignment
operations
are
performed.
Pump
and
motor
were
aligned
before
dispatch.
If
it
is
necessary
to
use
very
thick
shims
to
adjust
coupling
alignment
on
site
this
means
that
the
baseplate
is
twisted.
Leveling
has
to
be
modified.
Checking
the
coupling
alignment
:
Check
distance
between
the
two
half
couplings.
Check
radial
and
axial
deviation.
Several
types
of
flexible
couplings
can
be
used.
Refer
to
coupling
operating
instructions
to
know
adjustment
values
and
misalignment
limits.
Several
methods
can
be
used
to
make
coupling
alignment.
Choice
of
a
method
will
depend
on
the
type
of
equipments
available
on
site.
Two
operating
methods
are
briefly
described
hereafter.
They
can
be
used
if
basic
metrology
equipments
are
available
:
Using
a
straight
‐
edge
and
a
caliper
:
Содержание NOEH
Страница 2: ......
Страница 3: ...NOEH INSTALLATION ET MISE EN SERVICE FRAN AIS N M S n 4095567 Ed 3 10 13...
Страница 4: ...2...
Страница 22: ...FRAN AIS 20 12 1 1 PLAN EN COUPE HYDRAULIQUE SIMPLE VOLUTE HYDRAULIQUE DOUBLE VOLUTE 12 1 2 NOMENCLATURE...
Страница 24: ...FRAN AIS 22 13 DECLARATION CE...
Страница 25: ......
Страница 26: ...NOEH INSTALLATION AND OPERATING INSTRUCTIONS ENGLISH N M S n 4095567 Ed 3 10 13...
Страница 27: ...2...
Страница 44: ...ENGLISH 19 12 1 1 SECTIONAL DRAWING SINGLE VOLUTE CASING DOUBLE VOLUTE CASING...
Страница 46: ...ENGLISH 21 13 EC DECLARATION OF CONFORMITY...
Страница 47: ......