8000m Series
-
37
-
Function
Code
Function
Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
F8.07
Acceleration
time 4
0.1~3600s
0.1s
Defined
by inverter
model
○
F8.08
Deceleration
time 4
0.1~3600s
0.1s
○
F8.09
Skip frequency
1
0.00~F0.10
0.01Hz
0.00Hz
○
F8.10
Skip frequency
2
0.00~F0.10
0.01Hz
0.00Hz
○
F8.11
Skip frequency
bandwidth
0.00~F0.10
0.01Hz
0.00Hz
○
F8.12
FDT level
0.00~F0.10
0.01Hz 50.00Hz
○
F8.13
FDT lag
0.0~100.0%
0.1%
5.0%
○
F8.14
Detecting range
of reached
frequency
0.0~100.0% (Maxi.
frequency)
0.1%
0.0%
○
F8.15
Braking
threshold
voltage
115.0~140.0% (standard
DC bus voltage)
0.1%
120.0%
○
F8.16
Speed display
coefficient
0.1~999.9%
0.1%
100.0%
○
F8.17
Start/stop
selection when
running time is
over
0:Keep running
1:Stop
0
○
F8.18
Running time
setting
0~9999h
1h
9999
○
F8.19
Droop control
0.00Hz~10.00Hz
0.01Hz
0.00Hz
○
F8.20
Panel filter time
selection
0.00~10.00s
0.01s
0.10s
○