3.2.2 Fault Reset
When inverter malfunction occurs, it will display the relative fault
information. Use the STOP/ RESET key or terminals (determined
by F5 group) to reset the fault. After fault reset, inverter is at stand-
by status. If not reset when inverter is at fault status, it will keep
operation protection status and cannot run.
3.2.3 Password Setting
When F7.00 is set to be non-zero, the parameter will be the user’s
password. After exit the function code editing status, the password
will be effective after one minute. And then press the PRGM key
again to try to access the function code editing mode, the inverter
panel will display “0.0.0.0”. The password must be input correctly
to access it. If it is necessary to cancel the password function, set
F7.00 to zero.
Notice:
When the inverter is powered on, system will execute initialization
first and inverter panel displays “8000” with four lights on. After
initialization, inverter accesses into stand-by status.