8000m Series
-
20
-
Chapter 4 Function Code Table
Notice:
“
○
”: The parameters can be modified at stop or running status.
“
●
”: The parameters cannot be modified at running status.
“
◎
”: The parameters which are actual-detecting record value cannot be
modified.
Function
Code
Function
Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
F0 Group: Basic Parameters
F0.00
Control mode
selection
0: Sensorless vector
control
1:V/F control
1
●
F0.01
Control
command
source
0:Keypad
1:Terminals
2: Communication
(RS485)
0
●
F0.02
Keypad &
terminal
frequency up/
down control
0: Valid and saved when
power-off
1:Valid and not saved
when power-off
2: Invalid
3. Control is valid while
running, and is invalid
while stop. When stopped
or power off, the VFD will
not save data
0
○
F0.03
Master
frequency
setting source X
0: Up/down key
1: Potentiometer of panel
2: AVI terminal
3: Reserved
4: Reserved
5: Reserved
1
●