30
3. Engine starts or PTO engages - but blower will not operate.
a. Peer through guard and check that blower clutch is operating.
b. Only PTO models, no power at latching relay.
c. Check clutch electrical connections.
d. Clutch not operational - check remote cord. With master switch
on and guard switch actuated, use jumper wire
27
in remote
receptacle
7
. If blower starts, remote cord is defective.
e. Remote cord okay - check blower relay
28
. You will have
to remove thumb screw
29
to lower door
30
in order to
check the relay.
f. Check battery, clutch will not cycle or will slip if battery
is not fully charged.
g. Check for 12 volts at clutch.
h. Check that blower can be turned by hand.
If not - blower is defective.
i. Faulty clutch - replace.
4. Engine starts or PTO engages and blower operates - but machine
mechanisms will not operate.
a. Peer through guard and check that mechanism clutch is operating.
b. On PTO models, no power at latching relay.
c. Check clutch electrical connections.
d. Clutch not operational - check remote cord. With master switch on
and guard switch actuated and jumper wire in place, use jumper
wires
27
and
34
in remote receptacle
7
. If mechanism starts,
remote cord is defective.
e. E. Remote cord okay - check mechanism relay. Pull blue tab up to
lock relay contact. If mechanism starts, the relay is defective.
f. Check battery, clutch will not cycle or will slip if battery is not
fully charged.
g. Check for 12 volts at clutch.
h. Check shear key.
i. Faulty clutch - replace.
27
7
30
29
34
Содержание CertainTeed Volu-Matic 200
Страница 6: ...6 Introduction HOPPER AREA EMERGENCY STOP BUTTONS FRONT PANEL BLOWING HOSE CONNECTION SAFETY GUARD...
Страница 12: ...12 Operation...
Страница 22: ...22 Preventive Maintenance...
Страница 28: ...28 Troubleshooting...
Страница 32: ...32 Parts Drawings...
Страница 33: ...33...
Страница 34: ...34...
Страница 50: ...50 Maintenance Record DATE JOB DESCRIPTION PERFORMED BY...
Страница 51: ...51 DATE JOB DESCRIPTION PERFORMED BY...