![Sailor RT5022 Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/sailor/rt5022/rt5022_workshop-manual_800726042.webp)
Functional unit workshop service
VHF 5000 System
3-26
0608
(OCGP) – GPS/NMEA input
The option connector is the upper D-SUB 15 Male connector on the rear side (see Section “Interface
connections” in the installation section). The GPS input is a differential input on pins 12 and 13.
This section is consulted after the installation and sanity check of the GPS device has been performed.
(OCGP-01)
Secure option
connector screw
(OCGP-02)
Position
(OCGP-03)
Self test?
(Replace)
Replace BB
(base band
board)
Test Flow
Terminated
(Installation)
GPS unit
and cables
Passed
Passed
Failed
OK
Failed
40429
(OCGP-01)
Secure option
connector screw
(OCGP-02)
Position
(OCGP-03)
Self test?
(Replace)
Replace BB
(base band
board)
Test Flow
Terminated
(Installation)
GPS unit
and cables
Passed
Passed
Failed
OK
Failed
Fig. 9 (OCGP) - Option connector GPS tests
Reference
Operation/Test
Test Criteria
Comments/instructions
The 15-pole DSUB cable connector is
fixed to the transceiver using the
NOTE:
Refer to the installation section for
connector pin ratings.
Pass:
The header line must
Fail:
Any other: (invalid)
(manual) (GPS-OFF), shown
when external GPS equipment
is functioning, indicates the
NMEA connection is defect.
Pass:
The position is shown,
and the header line must
Fail:
“Not connected” is shown
in display.
OCGP-01 Secure option connector
OCGP-02 Verify position on Idle
screen
OCGP-03 Run GPS self test
The GPS test is executed by selecting
“GPS” in the accessory menu
5.6.
Tabel 5 (OCGP) - Option connector GPS tests