Technical data
ZDUE-LTE-PLUS-VII
Page 61 of 62
12
Technical data
Power supply:
Input voltage (Un) 100 VAC to 230 VAC +/-10%, 50Hz60
VDC to 100 VDC +/-10% (reverse polarity protected)
Current consumption (In) 65 mA @ 230 VAC
140 mA @ 60 VDC
Typical power consumption 3.2 W; logged into radio network, occasional data transmission
GSM interface:
Frequency bands GSM/GPRS/EDGE: 900/1800MHz
UMTS/HSPA+: 900/2100MHz
LTE: 700/800/900/1800/2100/2600MHz
Mobile phone connection GPRS; Support GPRS multi-slot class 33 (33 by default)
LTE CAT-1; bands B1/ B3/ B7/ B8/ B20/ B28A
SIM card ID-000 format (25mm x 15mm); 1.8V or 3V
Antenna connection SMA or FAKRA-D, approx. 50 Ohm
Meter interfaces:
CL1 Current interface (20mA) according to EN 62056-21, Mode A/C, up to 19.2
kbit/s
RS-232 Full duplex
Signals: Rx, Tx, DSR, GND
Speed: max. 38,400 baud (max. cable <length < 3 m)
Cable length: max. 15 m
RS-485 Signals: RT+, RT
Transceiver: max. 32
Speed: max. 19,200 baud
Cable length: max. 1000 m
Configuration EN 62056-21
Communication with meter Meter mode: EN 62056-21: Mode C, Mode A (corresponds to transparent)
AT mode: GSM data modem with AT command interface
Galvanic separation:
Test voltage
Power supply L1, N against all interfaces: 3 kVAC, 50 Hz, 1 min.
Between interfaces: 500 VAC, 50 Hz, 1min.
Climate conditions:
Temperature Operation:
- 20°C ... +55°C; +55°C ... +65°C (limited)
Storage:
- 25°C ... +85°C
Humidity 0 - 95 % relative, non-condensing
Содержание Dr. Neuhaus ZDUE-LTE-PLUS-VII