Communication commands according to EN 62056-21
ZDUE-LTE-PLUS-VII
Page 51 of 62
9.3.1
Write class (complete)
Function
Write class (complete)
Command format:
<SOH> W1<STX> C<class> 000000
(<data>)
(set-password)<ETX><BCC>
Note
After executing this command, the data is initially stored in the volatile memory
of the ZDUE-LTE-PLUS-VII. To transfer the data to the non-volatile memory, the
parameter transfer command
W1P01
() (see chapter 9.3.3) must be executed.
Example:
Set the parameters of the subgroup parameter class 79 to the following values:
EVU identifier:
‘12345678’
Device address:
‘74747474’
Set password:
‘18871887’
Head end system password active
'0'.
Head end system password:
'PW0'
Communication ID:
'1KGL923390R0003'
Data format to the meter:
'1
Mode C monitoring:
‘1’
Transfer timeout:
‘99’
…
(The other parameters accordingly)
Command
Answer
Command
Answer
Command
Answer
Command
Answer
/?99999999!<CR><LF>
/ABB61KGL923390R0003<CR><LF>
<ACK>061<CR><LF>
<SOH>P0<STX>(00000001)<ETX><BCC>
<SOH>P1<STX>(00000000)<ETX><BCC>
<ACK>
<SOH>W1<STX>C7900000000(081234567800000000
08747474740000000008188718870000000000PW000
00000000000151KGL923390R0003011990160000002
1000140000000001150)(00000000)<ETX><BCC>
<ACK>