S
Proc Sheet 1 08
myX-6/myV-65
REMOVING / REPLACING THE MICROPHONE
1/2
Ref. SCT U38 SSC DTS 0012 – Index A - May 12 , 2003
Page 5-29
Tools :
- A 0.6mm torx screwdriver
- Tweezers
Preliminary operation
1. Remove the back cover (
Proc sheet 0 01
).
2. Remove the battery (
Proc sheet 0 02
).
3. Remove the front cover (
Proc sheet 0 03
).
4. Unscrew the six attachment screws on the electronic board.
5. Remove the assembly display , then the light guide keypad
(Proc sheet 1 02 / 1 03)
6. Remove the electronic board.(
Proc sheet 1 04
)
Removal procedure:
1. Remove the microphone (1) , using tweezers.
Placement procedure :
1. Put the microphone (1) in position in its housing .
Further operations :
1. Remove the electronic board on the assembly plate. .(
Proc sheet 1 04
)
2. Replace the light guide keypad
(Proc sheet 1.03
)
3. Replace the assembly display
(Proc sheet 1 02)
4. Position and tighten the six attachments screws with torx settings of
0,25 N.m.
5. Replace the front cover /battery / back cover (
Proc sheet 0 01 / 0 02 / 0 03)
.
6.
Carry out the radio test (
Test Sheet 06
).