S
Test Sheet 04
1/1
myX-6/myV-65
CONSUMPTION TEST
Ref. SCT U38 SSC DTS 0012 – Index A - May 12 , 2003
Page 4-18
Test description
This test tests the battery consumption.
Required tools
−
myX-6 Ammeter interface
−
An Ammeter.
Test procedure
Measurement when switched off
1. Insert the mobile (switched off) onto the tool (customer phone and battery).
2. Connect the ammeter to the tool between A poles:
−
Red tool terminal on the ammeter "
COM
" or "
GND
" terminal.
−
Black tool terminal on the ammeter "
+
" terminal.
NOTE: The ammeter rating must be set to DC (DC or =), range 100 mA.
3. If the value indicated exceeds 1 mA ,the mobile is defective.
Measuring the charge
1.
Insert the mobile (switched off) onto the tool (customer phone and battery).
2. Connect the ammeter to the tool between A poles:
−
Black tool terminal on the ammeter "
COM
" or "
GND
" terminal.
−
Red tool terminal on the ammeter "
+
" terminal.
NOTE: The ammeter rating must be set to DC (DC or =), range 1 A.
3. Connect the customer's charger when energised (after connecting the charger to the mains power
supply).
4. If the value indicated is lower than 150 mA ,the mobile is defective.
NOTE: When changing the ammeter rating (manual or automatic), the mobile can be disconnected.