11.2. BASE WIRE CONNECTIONS
Reminder of safety procedures:
Select an electrical socket that complies with the general safety instruction given in
chapter 1 of this present document.
P base (base for EFT930P or EFT930G with Modem option)
Rear view of base
A
=
possible telephone
B
=
telephone plug
C
=
interface to the telephone line
D
=
telephone network wall socket
E
=
mains power supply network
F
=
power supply unit
G
=
plug for telephone network
H
=
plug for power supply
I
=
serial link (local loading tool, cash register)
J
=
socket for telephone device
Perform the following operations:
−
Connect the base to the telephone network
• Connect telephone plug
C,
equipped if necessary with user country specific
telephone plug, to the telephone network
D
.
• Connect the other end of the wire to the base (socket
G
),
• Connect the mains power supply wire to the base (socket
H
),.
• If necessary, connect the telephone
A.
(Telephone
A
is not required for the terminal to operate).
- France: plug
B
to the telephone network D through the piggyback plug
- other countries: telephone connected to the base through the socket
J
(RJ-
type connector).
−
Connect power supply block
F
to the mains electrical socket
E
.
Socket G (=socket J):
TNV-3 circuit: Telecommunication Network Voltage, as per
safety standard EN 60950.
Socket I:
SELV circuit: Since these links are Safety Extra Low Voltage circuits, they
must be interconnected to units which have interfaces powered by the same type of
circuits.
Connecting is to be made when the terminal is off.