Sage Technologies
36
Battery Replacement
Supplies needed for changing the battery on the Acoustic Fluid Logger are:
•
Large flathead screwdriver
•
Medium and small Phillips screwdrivers
•
5/16" wrench
•
New 12-volt 7.0 amp standard motorcycle battery.
First, using the medium Phillips screwdriver, remove the ten outermost screws on the Acoustic
Fluid Logger front panel – two on each side and three at the top and three at the bottom of the panel.
These screws attach the front panel to the box.
Lift up the front panel, which will require shifting the panel to the side, to remove the entire panel
and internal circuit boards and wiring from the box. Be careful not to disconnect the cables. Flip the panel
over to allow access to the battery box. Disconnect the red and yellow battery wire connections from the
battery.
Warning: DO NOT work on the front panel with the battery still connected.