Pressure Pulse Gun – Maintenance
Most supplies needed for care and maintenance are included with the Pressure Pulse Gun at time
of purchase:
•
O-ring kit containing seven O-rings (two small black, two medium black, one small white
and one large black) and 2 valve cores.
•
Gun maintenance tool
•
3/16" ball-end socket
•
Two 5/32" Allen wrenches
Also helpful for use in repair are the following supplies:
•
Standard channel lock pliers
•
Large flathead screwdriver
•
Tube of silicon lubricant (found at most oilfield or auto supply stores.)
When disassembling the gun for maintenance, first remove the internal microphone. To
remove the microphone, first remove the microphone retainer bolt from the bottom of the gun, using a
flathead screwdriver, as shown below. Then pull the microphone out of the bottom of the gun, being
careful to hold the microphone by the stainless steel sides so as not to damage the round microphone
crystals.
If the microphone is dirty, wipe it clean, by holding the microphone by the stainless steel parts
and by
avoiding
pressing on the circular microphone crystals on either side of the microphone head.