21
3. “Up / Down Pushbutton” Function Setting:
Item
Content
Description
A
Normal/Normal (Interlock)
Normal/Normal (Non-Interlock)
Normal/Toggle (Control by EMS)
Toggle/Normal (Control by EMS)
Toggle/Toggle (Control by EMS)
Off /On (Control by EMS)
“Normal/Normal (Interlock)”:
When “Up” or “Down” is
pressed, if the other is pressed too, then both of them will
be off.
“Normal/Normal (Non-Interlock)”:
Both of “Up” and
“Down” work independently or simultaneously when they
were pressed at the same time.
“Normal/Toggle (Control by EMS)”:
“Up” is on when
pressed, off when released; “Down” is on once pressed, off
when pressed again.
“Toggle/Normal (Control by EMS)”:
Reverse to above
description.
“Toggle/Toggle (Control by EMS)”:
Both “Up” and
“Down” work once pressed, off when pressed again
independently.
“Off/On (Control by EMS)”:
“Down” is on once pressed,
off when “Up” is pressed afterwards.
4. “East / West Pushbutton” Function Setting:
Same as
“Up / Down Pushbutton” Function Setting
5.“South / North Pushbutton” Function Setting:
Same as
“Up / Down Pushbutton” Function Setting
6.“Transmitter” Function Setting:
item
Title
Content
Description
A
Transmit
Mode
1. Continuous
2. Non-Continuous
“Continuous”:
The signal is transmitting to the receiver
by transmitter continuously during “Power-On”.
“Non-Continuous”:
The signal is transmitting to the
receiver only when pushbutton on transmitter is pressed.
B
Power
saving
*
1. Enable
2. Disable
“Enable”:
Enable the “power saving mode”.
“Disable”:
Disable this function.
C. Save-
Power
1. 1 min~30 min
2. Non-Execute
PS.
Only
appears
when the Transmitter
Mode is “Continuous”
“1 min~30 min”:
Choose the due time for the transmitter
to cut off its own power if no operation signal sending out
by any pushbutton pressed to save power.
“Non-Execute”:
Disable this function.